MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/os.13714

Медицинская библиотека · Orthopaedic surgery · 2023

Elbow Kinematics and Function Following Treatment with Open Arthrolysis and Hinged External Fixator.

Ling Ming, Liang Zhenming, Wang Yanmao, Cheng Mengqi, Lu Shengdi, Pan Yao, Hu Hai, Chen Bin, Ding Jian

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

Open arthrolysis (OA) combined with hinged external fixator (HEF) is a promising surgical option for patients with elbow stiffness. This study aimed to investigate elbow kinematics and function following a combined treatment with OA and HEF in elbow stiffness cases.

METHODS

Patients treated with OA with or without HEF due to elbow stiffness were recruited between August 2017 and July 2019. Elbow flexion-extension motion and function (Mayo elbow performance scores, MEPS) were recorded and compared between patients with and without HEF during a 1-year follow-up period. Additionally, those with HEF were assessed by dual fluoroscopy at week 6 postoperatively. Flexion-extension and varus-valgus motions, as well as ligament insertion distances of the anterior medial collateral ligament (AMCL) and lateral ulnar collateral ligament (LUCL), were compared between the surgical and intact sides.

RESULTS

This study included 42 patients, of which 12 with HEF demonstrated a similar flexion-extension angle and range of motion (ROM) and MEPS as the other patients. In patients with HEF, the surgical elbows showed limitations in flexion-extension (maximal flexion, 120.5° ± 5.3° vs 140.4° ± 6.8°; maximal extension, 13.1° ± 6.0° vs 6.4° ± 3.0°; ROM, 107.4° ± 9.9° vs 134.0° ± 6.8°; all Ps < 0.01) compared with the contralateral sides. During elbow flexion, a gradual valgus-to-varus transition of the ulna, increase in the AMCL insertion distance, and steady change in the LUCL insertion distance were observed, with no significant differences between the bilateral sides.

CONCLUSIONS

Patients treated with OA and HEF demonstrated similar elbow flexion-extension motion and function to those treated with OA alone. Although the use of HEF could not restore an intact flexion-extension ROM and might result in some minor but not significant changes in kinematics, it contributed to clinical outcomes comparable to that of the treatment with OA alone.

Для цитирования: Ling Ming, Liang Zhenming, Wang Yanmao, Cheng Mengqi, Lu Shengdi, Pan Yao, Hu Hai, Chen Bin, Ding Jian. Elbow Kinematics and Function Following Treatment with Open Arthrolysis and Hinged External Fixator.. Orthopaedic surgery. 2023. DOI: 10.1111/os.13714.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.