MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.injury.2017.05.031

Медицинская библиотека · Injury · 2017

Modified dynamic hip screw loaded with autologous bone graft for treating Pauwels type-3 vertical femoral neck fractures.

Luo Deqing, Zou Weitao, He Yijiao, Xian Hang, Wang Lei, Shen Jiazuo, Lian Kejian, Lin Dasheng

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Management of Pauwels type-3 vertical femoral neck fractures has been a challenging clinical problem as they experience high shear forces and thus a greater risk of treatment failure. There is no apparent consensus on the optimal implant type for these injuries. We developed a modified dynamic hip screw (DHS), which was designed to a cage in the lag screw, loaded with autologous bone graft for the treatment of Pauwels type-3 vertical femoral neck fractures.

METHODS

Between February 2010 and January 2012, 17 consecutive patients with Pauwels type-3 vertical femoral neck fractures were treated with the modified DHS loaded with autologous bone graft. All patients were followed up for a minimum of 24 months (range, 24-36 months). Surgical details, operative and postoperative complications, the rates of nonunion and osteonecrosis and the Harris hip score were evaluated.

RESULTS

There were thirteen men and four women with a mean age of 37.2 years (range, 27-52 years). There were no intraoperative complications related to this technology. All fractures healed within 14.1 weeks (range, 12 to 20 weeks). One patient required total hip replacement because of avascular necrosis of the femoral head at 27 months after surgery. According to the Harris hip score, eleven patients (64.7%) had excellent results, four (23.5%) had good results, one (5.9%) had moderate and one (5.9%) had poor result.

CONCLUSIONS

The modified DHS loaded with autologous bone graft appears to be a reliable implant for the treatment of Pauwels type-3 vertical femoral neck fractures with fewer complications.

Для цитирования: Luo Deqing, Zou Weitao, He Yijiao, Xian Hang, Wang Lei, Shen Jiazuo, Lian Kejian, Lin Dasheng. Modified dynamic hip screw loaded with autologous bone graft for treating Pauwels type-3 vertical femoral neck fractures.. Injury. 2017. DOI: 10.1016/j.injury.2017.05.031.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.