MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.semarthrit.2022.152144

Медицинская библиотека · Seminars in arthritis and rheumatism · 2022

Hounsfield Units measured in low dose CT reliably assess vertebral trabecular bone density changes over two years in axial spondyloarthritis.

Marques Mary Lucy, da Silva Nuno Pereira, van der Heijde Désirée, Reijnierse Monique, Baraliakos Xenofon, Braun Juergen, van Gaalen Floris, Ramiro Sofia

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVES

To describe low dose Computed Tomography (ldCT) Hounsfield Units (HU) two-year change-from-baseline values (expressing trabecular bone density changes) and analyse their inter-reader reliability per vertebra in radiographic axial spondyloarthritis (r-axSpA).

METHODS

We used 49 patients with r-axSpA from the multicentre two-year Sensitive Imaging in Ankylosing Spondylitis (SIAS) study. LdCT HU were independently measured by two trained readers at baseline and two years. Mean (standard deviation, SD) for the change-from-baseline HU values were provided per vertebra by reader. Intraclass correlation coefficients (ICC; absolute agreement, two-way random effect), Bland-Altman plots and smallest detectable change (SDC) were obtained. Percentages of vertebrae in which readers agreed on the direction of change and on change >|SDC| were computed.

RESULTS

Overall, 1,053 (98% of all possible) vertebrae were assessed by each reader both at baseline and two years. Over two years, HU mean change values varied from -23 to 28 and 29 for reader 1 and 2, respectively. Inter-reader reliability of the two-year change-from-baseline values per vertebra was excellent: ICC:0.91-0.99; SDC:6-10; Bland-Altman plots were homoscedastic, with negligible systematic error between readers. Readers agreed on the direction of change in 88-96% and on change >|SDC| in 58-94% of vertebrae, per vertebral level, from C3 to L5. Overall, similar results were obtained across all vertebrae.

CONCLUSION

LdCT measurement of HU is a reliable method to assess two-year changes in trabecular bone density at each vertebra from C3-L5. Being reliable across all vertebrae, this methodology can aid the study of trabecular bone density changes over time in r-axSpA, a disease affecting the whole spine.

Для цитирования: Marques Mary Lucy, da Silva Nuno Pereira, van der Heijde Désirée, Reijnierse Monique, Baraliakos Xenofon, Braun Juergen, van Gaalen Floris, Ramiro Sofia. Hounsfield Units measured in low dose CT reliably assess vertebral trabecular bone density changes over two years in axial spondyloarthritis.. Seminars in arthritis and rheumatism. 2022. DOI: 10.1016/j.semarthrit.2022.152144.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.