MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00402-007-0365-0

Медицинская библиотека · Archives of orthopaedic and trauma surgery · 2007

Implant-related infection model in rat spine.

Ofluoglu Ender Ali, Zileli Mehmet, Aydin Derya, Baris Yakup Sancar, Kuçukbasmaci Omer, Gonullu Nevriye, Ofluoglu Onder, Toplamaoglu Halil

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

The rate of postoperative infections is approximately 1% in spine surgery. However, when metal implants are used, postoperative infection rates significantly increase and were reported between 2.1 and 8.5%. This study aim to set up an infection model in the rat spine with a metal implant.

MATERIALS AND

METHODS

Forty white male Sprague Dawley rats were randomly divided in four groups. In all rats, under operation microscope, a 3 mm titanium microscrew was implanted in the thoracolumbar area (T10-L1) after laminar decortication. In Group I (control group), sterile isotonic solution and in other three groups, different concentrations of Staphylococcus aureus [Group II: (10(2)), Group III: (10(3)), Group IV: (10(6))] were squirted on the decorticated lamina site. All animals were sacrificed after 2 weeks, and then blood cultures and cultures from fascia, muscle and bone were obtained. Bacterial number in each tissue was measured as colony-forming unit per gram tissue. Titanium microscrews were placed in 0.5 ml tryptic soy broth and vortexed than plated on trypticase soy agar to determine bacterial growth. Two animals from each group were subjected to histological examination.

RESULTS

Blood cultures obtained by intra-atrial puncture after 2 weeks were negative in all groups indicating no systemical infection developed. Bacterial cultures were negative in all specimens of Group I (control group). A significant osseous infection was confirmed in Groups II, III and IV. Comparison of bacterial counts in bone cultures showed no significant difference between Group III (10(3) CFU/10 microl) and Group IV (10(6) CFU/10 microl) (P > 0.05), while both groups had significantly higher counts than Group II (10(2) CFU/10 microl) (P > 0.05). Microscopic findings of supurrative inflammation were present only in Group IV (10(6) CFU/10 microl).

CONCLUSIONS

This study shows that inoculation of S. aureus in 10(6) CFU/10 microl concentration at the decorticated lamina after implantation of a titanium screw in rat spine is a reproducible model for spinal infection and can be used for the animal model of prophylaxis and treatment and of postoperative infection.

Для цитирования: Ofluoglu Ender Ali, Zileli Mehmet, Aydin Derya, Baris Yakup Sancar, Kuçukbasmaci Omer, Gonullu Nevriye, Ofluoglu Onder, Toplamaoglu Halil. Implant-related infection model in rat spine.. Archives of orthopaedic and trauma surgery. 2007. DOI: 10.1007/s00402-007-0365-0.