MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s10195-021-00569-9

Медицинская библиотека · Journal of orthopaedics and traumatology : official journal of the Italian Society of Orthopaedics and Traumatology · 2021

Risk factors for refracture of the femoral shaft in children after removal of external fixation.

Guo Meizhen, Su Yuxi

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

External fixation is the primary treatment option in children for femoral shaft fractures, such as open femoral or multiple fractures. One complication is refracture, which is the biggest limitation of fixation devices. This study aims to investigate the risk factors associated with refracture after the removal of external fixation devices and decrease the frequency of refracture.

MATERIALS AND

METHODS

Retrospectively reviewed clinical data of 165 patients treated at our hospital for fresh femoral shaft fractures with external fixation between May 2009 and February 2018 were included in this study. Patients with pathological fractures, fractures of the femoral neck, fractures that were fixed using plates or elastic stable intramedullary nailing, and old fractures, as well as those who underwent postoperative femoral surgery were excluded. Potential risk factors included: patient age, gender, and weight, fracture sides, open or closed fracture, fracture sites, reduction methods, operation time, perioperative bleeding, number and diameter of the screws, and immobilization time. These factors were identified by univariate and logistic regression analyses.

RESULTS

Femoral shaft refracture developed in 24 patients. Univariate analysis revealed that refracture was not statistically significantly associated with any of the above factors, except AO Pediatric Comprehensive Classification of Long Bone Fractures (PCCF) classification type 32-D/4.2 and L2/L3 ratio (L2, length of femur fixed by the two screws farthest from the fracture line; L3, the total length from the greater trochanter to the distal end of femur; P < 0.001 and P = 0.0141, respectively). Multivariate analysis showed that PCCF classification type 32-D/4.2 and L2/L3 ratio were also independent risk factors for femoral refracture.

CONCLUSIONS

Femoral shaft refracture is relatively common in children treated with external fixation. Because of the limited number of cases in this study, we cautiously concluded that the PCCF classification type 32-D/4.2 and L2/L3 ratio were independent risk factors for femoral shaft refracture in these patients.

LEVEL OF EVIDENCE: IV.

Для цитирования: Guo Meizhen, Su Yuxi. Risk factors for refracture of the femoral shaft in children after removal of external fixation.. Journal of orthopaedics and traumatology : official journal of the Italian Society of Orthopaedics and Traumatology. 2021. DOI: 10.1186/s10195-021-00569-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.