Novel artificial intelligence model predicts the need for reduction of distal radius fractures.

Scioscia Jacob, Fiedler Benjamin, Ghilzai Umar, Birhiray Dion, Hauck Jeffrey, Chilukuri Srikhar, Vemu Rohan, Morrow Joshua, Deveza Lorenzo

СтатьяПеревод в очереди

Аннотация

PURPOSE: Distal radius fractures are among the most common upper extremity injuries. While convolutional neural networks (CNNs) have shown promise in fracture detection, no models have specifically addressed the need for reduction, which is a critical distinction for clinical decision-making. Current AI models detect fractures but fall short in guiding treatment, highlighting an opportunity to enhance triage through AI.

METHODS

We retrospectively assembled 495 patients with AP, lateral, and oblique wrist radiographs. To mirror real-world deployment, images were smartphone-style screenshots standardized to 224 × 224 grayscale. We trained BoraeNet, a three-branch DenseNet-169 model (one branch per view) using 5-fold CV on 90% of patients and evaluated a held-out internal test set (n = 50).

RESULTS

BoraeNet demonstrated strong performance in classifying fractures needing reduction. Training metrics included accuracy (0.93), precision (0.95), recall (0.91), and F1 score (0.93), with consistent performance across folds. On the held-out internal validation set (n = 50), the model achieved an AUC of 0.89 and average precision of 0.91, classifying 15 true positives, 27 true negatives, 6 false positives, and 2 false negatives.

CONCLUSION

The BoraeNet model offers a promising tool using low-fidelity images to predict need for reduction with strong discrimination, supporting triage in resource-limited settings. Future work should include larger datasets with demographic information, object detection, and multi-center external validation and integration into PACS/clinical workflow. Level of Evidence Level III.

Для цитирования: Scioscia Jacob, Fiedler Benjamin, Ghilzai Umar, Birhiray Dion, Hauck Jeffrey, Chilukuri Srikhar, Vemu Rohan, Morrow Joshua, Deveza Lorenzo. Novel artificial intelligence model predicts the need for reduction of distal radius fractures.. European journal of orthopaedic surgery & traumatology : orthopedie traumatologie. 2025. DOI: 10.1007/s00590-025-04592-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.