DOI 10.1089/jamp.2023.0023

Медицинская библиотека · Journal of aerosol medicine and pulmonary drug delivery · 2023

Tracheomalacia Reduces Aerosolized Drug Delivery to the Lung.

Gunatilaka Chamindu C, McKenzie Christopher, Hysinger Erik B, Xiao Qiwei, Higano Nara S, Woods Jason C, Bates Alister J

СтатьяПоддержка NIH: внешняя программаПеревод в очереди

Аннотация

Rationale: Neonates with respiratory issues are frequently treated with aerosolized medications to manage lung disease or facilitate airway clearance. Dynamic tracheal collapse (tracheomalacia [TM]) is a common comorbidity in these patients, but it is unknown whether the presence of TM alters the delivery of aerosolized drugs.

Objectives

To quantify the effect of neonatal TM on the delivery of aerosolized drugs.

Methods

Fourteen infant subjects with respiratory abnormalities were recruited; seven with TM and seven without TM. Respiratory-gated 3D ultrashort echo time magnetic resonance imaging (MRI) was acquired covering the central airway and lungs. For each subject, a computational fluid dynamics simulation modeled the airflow and particle transport in the central airway based on patient-specific airway anatomy, motion, and airflow rates derived from MRI.

Results

Less aerosolized drug reached the distal airways in subjects with TM than in subjects without TM: of the total drug delivered, less particle mass passed through the main bronchi in subjects with TM compared with subjects without TM (33% vs. 47%, p = 0.013). In subjects with TM, more inhaled particles were deposited on the surface of the airway (48% vs. 25%, p = 0.003). This effect becomes greater with larger particle sizes and is significant for particles with a diameter >2 μm (2-5 μm, p ≤ 0.025 and 5-15 μm, p = 0.004).

Conclusions

Neonatal patients with TM receive less aerosolized drug delivered to the lungs than subjects without TM. Currently, infants with lung disease and TM may not be receiving adequate and/or expected medication. Particles >2 μm in diameter are likely to deposit on the surface of the airway due to anatomical constrictions such as reduced tracheal and glottal cross-sectional area in neonates with TM. This problem could be alleviated by delivering smaller aerosolized particles.

Для цитирования: Gunatilaka Chamindu C, McKenzie Christopher, Hysinger Erik B, Xiao Qiwei, Higano Nara S, Woods Jason C, Bates Alister J. Tracheomalacia Reduces Aerosolized Drug Delivery to the Lung.. Journal of aerosol medicine and pulmonary drug delivery. 2023. DOI: 10.1089/jamp.2023.0023.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.