MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.crad.2015.08.011

Медицинская библиотека · Clinical radiology · 2015

The classification of osteonecrosis in patients with cancer: validation of a new radiological classification system.

Niinimäki T, Niinimäki J, Halonen J, Hänninen P, Harila-Saari A, Niinimäki R

СтатьяВалидационное исследованиеПеревод в очереди

Аннотация

AIM: To validate a new, non-joint-specific radiological classification system that is suitable regardless of the site of the osteonecrosis (ON) in patients with cancer.

MATERIAL AND

METHODS

Critical deficiencies in the existing ON classification systems were identified and a new, non-joint-specific radiological classification system was developed. Seventy-two magnetic resonance imaging (MRI) images of patients with cancer and ON lesions were graded, and the validation of the new system was performed by assessing inter- and intra-observer reliability.

RESULTS

Intra-observer reliability of ON grading was good or very good, with kappa values of 0.79-0.86. Interobserver agreement was lower but still good, with kappa values of 0.62-0.77. Ninety-eight percent of all intra- or interobserver differences were within one grade. Interobserver reliability of assessing the location of ON was very good, with kappa values of 0.93-0.98.

CONCLUSION

All the available radiological ON classification systems are joint specific. This limitation has spurred the development of multiple systems, which has led to the insufficient use of classifications in ON studies among patients with cancer. The introduced radiological classification system overcomes the problem of joint-specificity, was found to be reliable, and can be used to classify all ON lesions regardless of the affected site.

Для цитирования: Niinimäki T, Niinimäki J, Halonen J, Hänninen P, Harila-Saari A, Niinimäki R. The classification of osteonecrosis in patients with cancer: validation of a new radiological classification system.. Clinical radiology. 2015. DOI: 10.1016/j.crad.2015.08.011.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.