High Reproducibility of an Automated Measurement of Mobility for Patients with Axial Spondyloarthritis.

Garrido-Castro Juan L, Curbelo Rafael, Mazzucchelli Ramón, Domínguez-González María E, Gonzalez-Navas Cristina, Flores Robles Bryan J, Zarco Pedro, Mulero Juan, Cea-Calvo Luis, Arteaga María J, Font-Ugalde Pilar, Carmona Loreto, Collantes-Estevez Eduardo

СтатьяНаблюдательное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

Conventional measures of spinal mobility used in the assessment of patients with axial spondyloarthritis (axSpA), such as the Bath Ankylosing Spondylitis Metrology Index and its components, are subject to interobserver variability. The University of Córdoba Ankylosing Spondylitis Metrology Index (UCOASMI) is a validated composite index based on a motion video-capture system, UCOTrack. Our objective was to assess its reproducibility in clinical practice settings.

METHODS

We carried out an observational study of repeated measures in 3 centers. Video-capture systems were installed and adapted to clinical rooms. Patients with axSpA and stable disease were selected by consecutive stratified sampling [disease duration, sex, and the Bath Ankylosing Spondylitis Disease Activity Index (BASDAI)]. Intraobserver reliability of the UCOASMI and of conventional measures was tested 3-5 days apart. For interobserver reliability, 3 patients from each center were evaluated in the other centers, within 3-7 days. The intraclass correlation coefficients (ICC) were calculated.

RESULTS

Thirty patients were included (73% men, mean age 53 yrs, mean BASDAI 3.0). Interobserver and intraobserver ICC of the UCOASMI was 0.98. Conventional measurements showed lower but adequate reproducibility as well, except for interobserver reliability of lateral flexion (0.41), cervical rotation (0.61), and Schöber test (0.07), and intraobserver reliability of tragus-to-wall distance (0.30).

CONCLUSION

Reproducibility of the UCOASMI seems very high, and apparently more reliable than conventional measures of mobility.

Для цитирования: Garrido-Castro Juan L, Curbelo Rafael, Mazzucchelli Ramón, Domínguez-González María E, Gonzalez-Navas Cristina, Flores Robles Bryan J, Zarco Pedro, Mulero Juan, Cea-Calvo Luis, Arteaga María J, Font-Ugalde Pilar, Carmona Loreto, Collantes-Estevez Eduardo. High Reproducibility of an Automated Measurement of Mobility for Patients with Axial Spondyloarthritis.. The Journal of rheumatology. 2018. DOI: 10.3899/jrheum.170941.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.