MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3233/xst-200786

Медицинская библиотека · Journal of X-ray science and technology · 2021

Quality improvement of general anteroposterior radiographic image of vertebral body according to optimum angle of incidence.

Kwak Jong Hyeok, Lee Chi Hyung, Kim Gyeong Rip, Lee Sang Weon, Kim Young Ha, Song Geun Sung, Son Dong Wuk, Sung Hynu Chul, Kwak Jin Sung, Sung Soon Ki

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

In this study, we present an appropriate angle of incidence to reduce the distortions in images of L4 and L5 during a general anteroposterior radiograph examination.

METHOD: We selected 170 patients who had normal radiological findings among those who underwent anteroposterior and lateral examination for lumbar vertebrae. An optimum angle of incidence wa suggested through the statistical analysis by measuring the lumbar lordosis angle and the intervertebral disc angle in these 170 patients.

RESULT: We suggested the incident angle (10.28°) of L4 and the incident angle (23.49°) of L5. We compared the distorted area ratios when the incident angle was 0°, 10°, and 23.5° using the ATOM® phantom. The ratio for the L4 decreased from 14.90% to 12.11% and that of the L5 decreased from 15.25% to 13.72% after applying the angle of incidence. We determined the incident angle (9.34°) of L4 and (21.26°) of L5 below 30° of LLA. Thus, we determined the incident angle (11.21°) of L4 and (25.73°) of L5 above 30° of LLA.

CONCLUSION

When you apply the optimum angle of incidence, the distortion of image was minimized and an image between the joints adjacent to the anteroposterior vertebral image with an accurate structure was obtained. As a result, we were able to improve the quality of the image and enhance diagnostic information.

Для цитирования: Kwak Jong Hyeok, Lee Chi Hyung, Kim Gyeong Rip, Lee Sang Weon, Kim Young Ha, Song Geun Sung, Son Dong Wuk, Sung Hynu Chul, Kwak Jin Sung, Sung Soon Ki. Quality improvement of general anteroposterior radiographic image of vertebral body according to optimum angle of incidence.. Journal of X-ray science and technology. 2021. DOI: 10.3233/xst-200786.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.