Marinelli Luca, Lo Mastro Antonio, Grassi Francesca, Berritto Daniela, Russo Anna, Patanè Vittorio, Festa Anna, Grassi Enrico, Grandone Anna, Nasto Luigi Aurelio, Pola Enrico, Reginelli Alfonso

Аннотация

BACKGROUND: Bone age assessment is essential in evaluating pediatric growth disorders. Artificial intelligence (AI) systems offer potential improvements in accuracy and reproducibility compared to traditional methods.

OBJECTIVE: To compare the performance of a commercially available artificial intelligence-based software (BoneView BoneAge, Gleamer, Paris, France) against two human-assessed methods-the Greulich-Pyle (GP) atlas and Tanner-Whitehouse version 2 (TW2)-in a pediatric population.

MATERIALS AND METHODS: This proof-of-concept study included 203 pediatric patients (mean age, 9.0 years; range, 2.0-17.0 years) who underwent hand and wrist radiographs for suspected endocrine or growth-related conditions. After excluding technically inadequate images, 157 cases were analyzed using AI and GP-assessed methods. A subset of 35 patients was also evaluated using the TW2 method by a pediatric endocrinologist. Performance was measured using mean absolute error (MAE), root mean square error (RMSE), bias, and Pearson's correlation coefficient, using chronological age as reference.

RESULTS: The AI model achieved a MAE of 1.38 years, comparable to the radiologist's GP-based estimate (MAE, 1.30 years), and superior to TW2 (MAE, 2.86 years). RMSE values were 1.75 years, 1.80 years, and 3.88 years, respectively. AI showed minimal bias (-0.05 years), while TW2-based assessments systematically underestimated bone age (bias, -2.63 years). Strong correlations with chronological age were observed for AI (r=0.857) and GP (r=0.894), but not for TW2 (r=0.490).

CONCLUSION: BoneView demonstrated comparable accuracy to radiologist-assessed GP method and outperformed TW2 assessments in this cohort. AI-based systems may enhance consistency in pediatric bone age estimation but require careful validation, especially in ethnically diverse populations.