Lower-limb muscle mass quantification and whole-body muscle loss detection using preoperative computed tomography images in patients with hip disease.

Sotaro Kono, Uemura Keisuke, Soufi Mazen, Nishimura Ryosuke, Miyamoto Takuma, Higuchi Ryo, Mae Hirokazu, Takashima Kazuma, Otake Yoshito, Tanaka Yasuhito, Takao Masaki, Sugano Nobuhiko, Okada Seiji, Hamada Hidetoshi

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

PURPOSE: This study developed a method for assessing lower-limb lean mass measured by dual-energy X-ray absorptiometry (DXA-LMleg), using lower-limb muscle mass derived from computed tomography images (CT-MM). Further, the diagnostic performance of the model in detecting whole-body muscle mass (MM) loss, a key component in the assessment of sarcopenia, was evaluated using CT-MM to facilitate the timely initiation of treatment as needed.

METHODS

This retrospective study enrolled 227 patients who underwent hip surgery at two institutions. A deep neural network (DNN)-based method was employed in segmenting lower-limb CT images taken for surgical planning, and the CT-MM was calculated using two different density conversion methods: CT-MM1 (CT-MM calculated using the conventional method) and CT-MM2 (CT-MM calculated using the method by Aubrey et al.). Both CT-MMs were correlated with DXA-LMleg, and receiver operating characteristic (ROC) curve analysis was performed to evaluate the diagnostic accuracy of CT-MMs in detecting whole-body MM loss.

RESULTS

In 222 cases that were successfully automatically analyzed, strong correlations were observed between CT-MM1 and DXA-LMleg (rs = 0.92-0.96) and between CT-MM2 and DXA-LMleg (rs = 0.86-0.92). ROC curve analysis revealed high diagnostic accuracy for whole-body MM loss (CT-MM1, area under the curve (AUC) = 0.96-0.97; CT-MM2, AUC = 0.91-0.93), with CT-MM1 demonstrating significantly better performance.

CONCLUSION

CT-MMs were strongly correlated with DXA-LMleg and had a high diagnostic performance (AUC > 0.9) in detecting whole-body MM loss, supporting sarcopenia screening and preoperative clinical decision-making using routine CT scan.

Для цитирования: Sotaro Kono, Uemura Keisuke, Soufi Mazen, Nishimura Ryosuke, Miyamoto Takuma, Higuchi Ryo, Mae Hirokazu, Takashima Kazuma, Otake Yoshito, Tanaka Yasuhito, Takao Masaki, Sugano Nobuhiko, Okada Seiji, Hamada Hidetoshi. Lower-limb muscle mass quantification and whole-body muscle loss detection using preoperative computed tomography images in patients with hip disease.. International journal of computer assisted radiology and surgery. 2025. DOI: 10.1007/s11548-025-03531-w.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.