DOI 10.1097/wnp.0000000000001118
Is Intraoperative Muscle Motor Evoked Potential Variability due to Fluctuating Lower Motor Neuron Background Excitability?
Аннотация
PURPOSE: This pilot study tests the contribution of fluctuating lower motor neuron excitability to motor evoked potential (MEP) variability.
METHODS
In six pediatric patients with idiopathic scoliosis and normal neurologic examination, cascades of 30 intraoperative H-reflexes (HRs) and MEPs were evoked in the soleus muscle using constant-current stimulators and recorded through surface electrodes with a 20-second interstimulus interval. First, HRs were obtained with an intensity capable of evoking the maximum response. Subsequently, MEPs were obtained with double trains and an intensity of 700 to 900 mA. Coefficients of variation (CVs) of amplitude and area under the curve from HRs and MEPs were compared using a paired two-tailed Student t test. Coefficients of correlation between the mean CVs of HR and MEP parameters were also assessed.
RESULTS
Pooling the results from the six patients, the mean CV of amplitude from the MEP (24.6 ± 3) was significantly higher than that from the HR (3.5 ± 4.4) ( P = 0.000091). The mean CV of the MEP area under the curve (21.8 ± 4.8) was also statistically significantly higher than that from the HR area under the curve (3.4 ± 4.5) ( P = 0.00091). The coefficients of correlation of the mean CV of the HR amplitude and area under the curve compared with the corresponding values of the MEP were low ( r = 0.29) and very low ( r = 0.03), respectively.
CONCLUSIONS
Our results suggest that fluctuations in lower motor neuron excitability may be less important than previously thought to explain the magnitude of MEP variability. The efficacy of corticospinal volleys to recruit a larger and more stable lower motor neuron population would be critical to obtain reproducible MEPs.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.