MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/(sici)1522-7243(199911/12)14:6<331::aid-bio556>3.0.co;2-e

Медицинская библиотека · Luminescence : the journal of biological and chemical luminescence · 1999

Applicability of chemiluminescence to assess the degree of operative stress in patients undergoing spinal surgery.

Kowatari K, Suzuki K, Kudo S, Yamada M, Liu Q, Danjo K, Umeda T, Nakaji S, Sugawara K

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

This study examined the applicability of luminol-dependent chemiluminescence (CL) response of neutrophils to assess the degree of stress of spinal surgery by measuring the capacity of circulating neutrophils to produce reactive oxygen species and the levels of serum cytokines: interleukin(IL)-1beta, IL-6, IL-8, tumour necrosis factor (TNF)-alpha and granulocyte colony stimulating factor (G-CSF). Ten male patients underwent spinal surgery. Peripheral blood samples, collected before and after the operation and the next morning, were used for measuring the CL response of neutrophils stimulated with opsonized zymosan and measuring the levels of serum cytokines. The operative stress induced leukocytosis, particularly granulocytosis, and increased serum IL-6 and G-CSF significantly. However, there was no significant change in the luminol-dependent CL response of neutrophils or the levels of serum IL-1beta, IL-8 and TNF-alpha throughout the experimental period. These results suggest that, at least in the early postoperative period, operative stress does not prime the circulating neutrophils, and thus the CL response of neutrophils is not appropriate to assess the degree of stress of spinal surgery.

Для цитирования: Kowatari K, Suzuki K, Kudo S, Yamada M, Liu Q, Danjo K, Umeda T, Nakaji S, Sugawara K. Applicability of chemiluminescence to assess the degree of operative stress in patients undergoing spinal surgery.. Luminescence : the journal of biological and chemical luminescence. 1999. DOI: 10.1002/(sici)1522-7243(199911/12)14:6<331::aid-bio556>3.0.co;2-e.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.