[Prevention of lateral cortex fractures in open wedge high tibial osteotomies : The anteroposterior drill hole approach].

Reyle G, Lorbach O, Diffo Kaze A, Hoffmann A, Pape D

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

In osteotomies with larger correction angles, the capacity for elastic deformation is frequently exceeded, resulting in plastic deformation and fracture of the opposite cortex, which may lead to subsequent loss of correction. An anteroposterior drill hole at the apex of the horizontal osteotomy (= hinge) is supposed to increase the capacity of the bony hinge for elastic deformation and ideally to prevent fractures of the opposite cortex.

MATERIALS AND

METHODS

A high tibial osteotomy (HTO) using standard surgical technique was performed in 20 each of Synbones, Sawbones, and human cadaver tibial specimens. In 10 specimens per group, an additional anteroposterior hinge drilling was performed at the apex of the horizontal osteotomy. All fractures of the opposite cortex were photographically and radiographically documented. All fractures were classified according to fracture types 1-3 of the Takeuchi classification.

RESULTS

Regardless of the study group, all tibial bones with an additional hinge drilling achieved larger correction angles during the spreading of the wedge until a fracture of the opposite cortex occurred. The average correction angle of all specimens without the drill hole was 2.7°, which increased to 4.8° with the hinge drill (increase by 77.8%). In correction angles exceeding 5°, all specimen showed a hinge fracture regardless of the presence or absence of a hinge drill.

CONCLUSIONS

The hinge-protecting effect is restricted to small correction angles, i. e., to unload cartilage repair regions in the absence of severe malalignment. For the treatment of varus gonarthrosis, there is no fracture-protecting effect from a hinge drill.

Для цитирования: Reyle G, Lorbach O, Diffo Kaze A, Hoffmann A, Pape D. [Prevention of lateral cortex fractures in open wedge high tibial osteotomies : The anteroposterior drill hole approach].. Der Orthopade. 2017. DOI: 10.1007/s00132-017-3418-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.