A Failed 4-Corner Arthrodesis Using a Polyether-Ether-Ketone Implant: A Case Report.

London Daniel A, Stern Peter J

Клинический случайСтатьяПеревод в очереди

Аннотация

CASE: A 59-year-old man underwent scaphoidectomy and 4-corner arthrodesis with a polyether-ether-ketone (PEEK) circular plate for scapholunate advanced collapse of the wrist. Five years later, he presented with a symptomatic nonunion and radiocarpal arthritis. Total wrist arthrodesis with a dorsal plate was performed. During revision surgery, considerable synovitis was encountered. Histological evaluation revealed a foreign body response likely secondary to PEEK particles.

CONCLUSION

Use of PEEK implants can result in an adverse local tissue reaction if particles are generated. This is a rare biomaterial-related complication, and surgeons should be aware of this adverse tissue response when using this or other PEEK implants.