MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.joca.2019.05.007

Медицинская библиотека · Osteoarthritis and cartilage · 2019

Dual-energy computed tomography in calcium pyrophosphate deposition: initial clinical experience.

Pascart T, Norberciak L, Legrand J, Becce F, Budzik J-F

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To determine the dual-energy computed tomography (DECT) attenuation properties of meniscal calcifications in calcium pyrophosphate deposition (CPPD) in vivo, and assess whether DECT was able to discriminate meniscal CPP deposits from calcium hydroxyapatite (HA) in subchondral and trabecular bone.

METHOD: Patients with clinical suspicion of crystal-related arthropathy (gout and/or CPPD) and knee DECT scans were retrospectively assigned to CPPD (n = 19) or control (n = 21) groups depending on the presence/absence of chondrocalcinosis on DECT. Two observers drew standardized regions of interest (ROI) in meniscal calcifications, non-calcified menisci, as well as subchondral and trabecular bone. Five DECT parameters were obtained: CT numbers (HU) at 80 and 140 kV, dual-energy index (DEI), electron density (ρe), and effective atomic number (Zeff). The four different knee structures were compared within/between patients and controls using linear mixed models, adjusting for confounders.

RESULTS

Meniscal calcifications (n = 89) in CPPD patients had mean ± SD CT numbers at 80 and 140 kV of 257 ± 64 and 201 ± 48 HU, respectively; with a DEI of 0.023 ± 0.007, and ρe and Zeff of 140 ± 35 and 8.8 ± 0.3, respectively. Meniscal CPP deposits were readily distinguished from calcium HA in subchondral and trabecular bone (p ≤ 0.001), except at 80 kV separately (p = 0.74). Zeff and ρe both significantly differed between CPP deposits and calcium HA in subchondral and trabecular bone (p < 0.0001).

CONCLUSION

This proof-of-concept study shows that DECT has the potential to discriminate meniscal CPP deposits from calcium HA in subchondral and trabecular bone in vivo, paving the way for the non-invasive biochemical signature assessment of intra- and juxta-articular calcium crystal deposits.

Для цитирования: Pascart T, Norberciak L, Legrand J, Becce F, Budzik J-F. Dual-energy computed tomography in calcium pyrophosphate deposition: initial clinical experience.. Osteoarthritis and cartilage. 2019. DOI: 10.1016/j.joca.2019.05.007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.