MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00330-025-11827-3

Медицинская библиотека · European radiology · 2025

Diagnostic interchangeability of deep-learning based Synth-STIR images generated from T1 and T2 weighted spine images.

Li Jie, Xu Meiling, Jiang Baiyang, Dong Qian, Xia Yi, Zhou Taohu, Lin Xiaoqing, Ma Yanqing, Jiang Song, Zhang Zhihao, Xiang Lei, Fan Li, Liu Shiyuan

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

To evaluate image quality and diagnostic interchangeability of synth short-tau inversion recovery (STIR) generated by deep learning in comparison with standard STIR.

MATERIALS AND

METHODS

This prospective study recruited participants between July 2023 and August 2023. Participants were scanned with T1WI and T2WI, then generated Synth-STIR. Signal-to-noise ratios (SNR), contrast-to-noise ratios (CNR) were calculated for quantitative evaluation. Four independent, blinded radiologists performed subjective quality and lesion characteristic assessment. Wilcoxon tests were used to assess the differences in SNR, CNR, and subjective image quality. Various diagnostic findings pertinent to the spine were tested for interchangeability using the individual equivalence index (IEI). Inter-reader and intra-reader agreement and concordance were computed, and McNemar tests were performed for comprehensive evaluation.

RESULTS

One hundred ninety-nine participants (106 male patients, mean age 46.8 ± 16.9 years) were included. Compared to standard-STIR, Synth-STIR reduces sequence scanning time by approximately 180 s, has significantly higher SNR and CNR (p < 0.001). For artifacts, noise, sharpness, and diagnostic confidence, all readers agreed that Synth-STIR was significantly better than standard-STIR (all p < 0.001). In addition, the IEI was less than 1.61%. Kappa and Kendall showed a moderate to excellent agreement in the range of 0.52-0.97. There was no significant difference in the frequencies of the major features as reported with standard-STIR and Synth-STIR (p = 0.211-1).

CONCLUSION

Synth-STIR shows significantly higher SNR and CNR, and is diagnostically interchangeable with standard-STIR with a substantial overall reduction in the imaging time, thereby improving efficiency without sacrificing diagnostic value.

KEY POINTS: Question Can generating STIR improve image quality while reducing spine MRI acquisition time in order to increase clinical spine MRI throughput? Findings With reduced acquisition time, Synth-STIR has significantly higher SNR and CNR than standard-STIR and can be interchangeably diagnosed with standard-STIR in detecting spinal abnormalities. Clinical relevance Our Synth-STIR provides the same high-quality images for clinical diagnosis as standard-STIR, while reducing scanning time for spine MRI protocols. Increase clinical spine MRI throughput.

Для цитирования: Li Jie, Xu Meiling, Jiang Baiyang, Dong Qian, Xia Yi, Zhou Taohu, Lin Xiaoqing, Ma Yanqing, Jiang Song, Zhang Zhihao, Xiang Lei, Fan Li, Liu Shiyuan. Diagnostic interchangeability of deep-learning based Synth-STIR images generated from T1 and T2 weighted spine images.. European radiology. 2025. DOI: 10.1007/s00330-025-11827-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.