MedElevator Войти в исследования
← Поиск публикаций

DOI 10.23750/abm.v91i4-s.9551

Медицинская библиотека · Acta bio-medica : Atenei Parmensis · 2020

Reinsertion of distal biceps ruptures with a single anterior approach: analysis of 14 cases using tension-slide technique and interference screw.

Micheloni Gian Mario, Tarallo Luigi, Porcellini Giuseppe, Novi Michele, Catani Fabio

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Several techniques of surgical repair of biceps tendon ruptures are described in literature. Cortical button repair have shown minimal loss of elbow flexion, supination and strength. In this retrospective study we report the outcomes in terms of elbow function and complications of tension-slide technique and interference screw. Matherials and methods: 14 patients with complete distal biceps tendon rupture were included in the retrospective study and treated with the same tension-slide technique (BicepsButton® - Arthrex, Inc, Naples, Florida) evaluating the clinical and functional outcomes and the complication rate with a follow-up average of 18 months.

RESULTS

The flexion recovered compare to the healthy contralateral was 96% (min 115° - max 135°; average 128°), the extension was 97% (min: -2° - max 15°; average 4°), the supination was 90% (min 20° - max 90°; average 75°), the pronation was 95% (min 15° - max 90°; average 76°). The mean Disabilities of Arm, Shoulder and Hand (DASH) score was 8.1 ± 10.5 and Mayo Elbow Performance Score overall (MEPS) score was 97.6 ± 8.2. Two patients had LABCN paresthesia, one case, treated 2 months after injury, had posterior interosseus nerve palsy. One patient had heterotopic ossification at the radiological examination without consequences for the clinical performances. No case of non-traumatic tendon re-rupture and no case of ROM deficiency > 20%. In all case the cortical button remains well positioned and no case of osteolysis were reported.

CONCLUSIONS

Distal biceps tendon repair with BicepsButton® system seems to be a safe, relyable and reproducible technique providing excellent clinical, functional and radiological outcomes. Comparing with other techniques the BicepsButton® system has the advantages of the single approach procedures, the reduction of surgical time and risk of heterotopic ossifications. (www.actabiomedica.it).

Для цитирования: Micheloni Gian Mario, Tarallo Luigi, Porcellini Giuseppe, Novi Michele, Catani Fabio. Reinsertion of distal biceps ruptures with a single anterior approach: analysis of 14 cases using tension-slide technique and interference screw.. Acta bio-medica : Atenei Parmensis. 2020. DOI: 10.23750/abm.v91i4-s.9551.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.