MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5137/1019-5149.jtn.13141-14.2

Медицинская библиотека · Turkish neurosurgery · 2016

New Dynamic Plate System Combined with Titanium Mesh Cage and Bone Graft in the Treatment of Cervical Spondylosis.

Wu Wenjie, Yang Yunbei, Liu Hao, Hong Yin, Gong Quan, Li Tao, Liu Limin, Song Yueming

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

AIM: Dynamic plates have been popularized to promote cervical spine fusion. There are no studies comparing the effectiveness and complications between traditional static plates and new dynamic plates (Vectra-T, Synthes, Switzerland).

MATERIAL AND

METHODS

From June 2009 to October 2012, 70 patients underwent anterior cervical corpectomy and fusion (ACCF) in our hospital for the treatment of cervical spondylosis. Vectra-T plate was used in 36 patients (dynamic group) while traditional static plate was used in 34 patients (static group). Sagittal section angle, sagittal plane mobility, coronal angle of the titanium mesh cage were measured and the change of sedimentation rate was calculated at the postoperative 3 < sup > rd < /sup > , 6 < sup > th < /sup > , 12 < sup > th < /sup > months and at the end of follow-up period for each patient. The Japanese Orthopedic Association (JOA) score and local cervical angle were also measured before, immediately after surgery and at the end of follow-up period. These data were compared for both groups.

RESULTS

The follow-up period was between 12 and 38 months. The clinical outcome was similar in both groups based on the JOA score, local cervical angle and regional cervical angle. All patients had good clinical outcome without fracture of the plates or screws. There were no differences between the two groups at the 3rd, 6th and 12th months after surgery regarding to fusion rate (p > 0.05). Settling of the construct and plate migration was similar between the groups at all time points.

CONCLUSION

There was no statistically significant difference between dynamic plates and static plates regarding to fusion rate. The clinical outcomes and radiographic changes were also similar in both groups.

Для цитирования: Wu Wenjie, Yang Yunbei, Liu Hao, Hong Yin, Gong Quan, Li Tao, Liu Limin, Song Yueming. New Dynamic Plate System Combined with Titanium Mesh Cage and Bone Graft in the Treatment of Cervical Spondylosis.. Turkish neurosurgery. 2016. DOI: 10.5137/1019-5149.jtn.13141-14.2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.