MedElevator Войти в исследования
← Поиск публикаций

DOI 10.7507/1002-1892.201610062

Медицинская библиотека · Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2017

[Effectiveness of distal femoral osteotomy assisted by three-dimensional printing technology for correction of valgus knee with osteoarthritis].

Chen Guoxian, Li Guoshan, Lin Zongjin, Chen Xuanhuang, Zhang Guodong, You Fengyuan, Chen Jinguo, Zeng Qingdong, Zheng Feng, Yu Zhengxi

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To evaluate the effectiveness of distal femoral osteotomy aided by three-dimensional (3D) printing cutting block for correction of vaglus knee with osteoarthritis.

METHODS

Between January 2014 and January 2016, 12 patients (15 knees) with vaglus deformity and lateral osteoarhritis underwent medial closing wedge distal femoral osteotomy. There were 5 males and 7 females, aged 30-60 years (mean, 43.8 years). The mean disease duration was 6.6 years (range, 1-12 years). The unilateral knee was involved in 9 cases and bilateral knees in 3 cases. According to Koshino's staging system, 1 knee was classified as stage I, 9 knees as stage II, and 5 knees as stage III. The X-ray films of bilateral lower extremities showed that the femorotibial angle (FTA) and anatomical lateral distal femoral angle (aLDFA) were (160.40±2.69)° and (64.20±2.11)° respectively. Mimics software was used to design and print the cutting block by 3D printing technique. During operation, the best location of distal femoral osteotomy was determined according to the cutting block. After osteotomy, internal fixation was performed using a steel plate and screws.

RESULTS

All incisions healed primarily; no complication of infection or deep vein thrombosis was observed. All patients were followed up 6-18 month (mean, 12.2 months). At 6 months after operation, the hospital for special surgery (HSS) score for knee was significantly improved to 89.07±2.49 when compared with preoperative score (65.27±1.49, t=-28.31, P=0.00); the results were excellent in 10 knees, good in 4 knees, and fair in 1 knee with an excellent and good rate of 93.3%. The bony union time was 2.9-4.8 months (mean, 3.3 months). Bone delayed union occurred in 1 case (1 knee). The postoperative FTA and aLDFA were (174.00±1.41)° and (81.87±1.06)° respectively, showing significant differences when compared with preoperative ones ( t=-18.26, P=0.00; t=-25.19, P=0.00). The percentage of medial tibial plateau in whole tibial plateau was 49.78%±0.59%, showing no significant difference when compared with intraoperative measurement (49.82%±0.77%, t=0.14, P=0.89).

CONCLUSION

3D printing cutting block can greatly improve the accuracy of distal femoral osteotomy, and ensure better effectiveness for correction of vaglus knee with osteoarthritis.

Для цитирования: Chen Guoxian, Li Guoshan, Lin Zongjin, Chen Xuanhuang, Zhang Guodong, You Fengyuan, Chen Jinguo, Zeng Qingdong, Zheng Feng, Yu Zhengxi. [Effectiveness of distal femoral osteotomy assisted by three-dimensional printing technology for correction of valgus knee with osteoarthritis].. Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery. 2017. DOI: 10.7507/1002-1892.201610062.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.