Comparison of Three Immunoassays for the Detection of Myositis Specific Antibodies.
Аннотация
Objectives
Standardization of myositis specific antibody (MSA) detection is of high importance because these antibodies are relevant for diagnosis and stratification of patients with idiopathic inflammatory myositis (IIM) and have the potential to be used in classification criteria. Many laboratories rely on immunoprecipitation (IP) for the detection of MSA but this approach is compromised by logistic, standardization, and regulatory challenges. Therefore, reliable alternatives to IP are mandatory. Here we aimed to compare three methods for the detection of MSA.
Methods
Our study initiated from a cohort of 1,619 IIM patients (BIRD/University of Bath serology service and UKMyoNet cohorts) and resulted in 157 unique serum samples enriched for higher prevalence of MSA characterized by the laboratory's routine methods, IP and line immunoassay (LIA: Euroimmun). All samples were tested using a novel fully automated particle-based multi-analyte technology (PMAT, Inova Diagnostics, research use only). Analyses included antibodies to PL-7, PL-12, SRP, NXP2, Mi-2, SAE, EJ, MDA5, TIF1γ, SRP, NXP2.
Results
Overall high agreements were observed between novel methods (LIA and PMAT) and IP (Cohen's kappa 0.46-0.96) for the detection of MSA. Lowest level of agreement was found for EJ and highest for SAE.
Conclusion
The data hold promise for advancements in standardization of MSA assays as well as for the potential inclusion of MSA in future classification criteria.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.