Yerlikaya Seda, Chirwa Masuzyo, Ajide Bukola, Castro Maria Del Mar, Ha Huy, Kato-Maeda Midori, Kisakye Esther, Marcelo Danaida, Mochizuki Tessa, Rockman Loren, Steadman Amy, Thangakunam Balamugesh, Bimba John Samson, Christopher Devasahayam J, Muyoyeta Monde, Phan Ha, Theron Grant, Yu Charles, Kremer Kristin, Phillips Patrick P J, Nahid Payam, Denkinger Claudia M, Cattamanchi Adithya, Andama Alfred, R2D2 TB Network and SMART4TB Consortia

Клиническое исследованиеСравнительное исследованиеСтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

BACKGROUND

Improved diagnostic tools for tuberculosis that are suitable for use in peripheral health centers are essential for reducing the persistent gap between estimated and notified cases. The diagnostic accuracy and usability of the MiniDock MTB test for detecting pulmonary tuberculosis is unknown.

METHODS

We conducted a prospective, cross-sectional study at outpatient centers in India, Nigeria, the Philippines, South Africa, Uganda, Vietnam, and Zambia. Patients 12 years of age or older with presumptive pulmonary tuberculosis were enrolled between September 12, 2024, and March 31, 2025. Assessment with MiniDock MTB was performed with sputum swabs and tongue swabs. Diagnostic accuracy was evaluated against a sputum-culture-based reference and as compared with sputum-smear microscopy and Xpert MTB/RIF Ultra assay. Usability was assessed with a system usability scale and direct observation.

RESULTS

A total of 1380 participants were enrolled; 255 (18.5%) had human immunodeficiency virus infection and 226 (16.4%) had culture-confirmed tuberculosis. MiniDock MTB sensitivity was 85.7% (95% confidence interval [CI], 80.4 to 90.0) with sputum and 79.6% (95% CI, 73.8 to 84.7) with tongue swabs; specificity was greater than 97.5% for both. Results of sputum tests with MiniDock MTB closely matched those with Xpert MTB/RIF Ultra for sensitivity (difference, -2.8 percentage points; 95% CI, -6.0 to 0.5). MiniDock MTB had greater sensitivity than smear microscopy for tests of sputum (difference, 24.3 percentage points; 95% CI, 17.9 to 30.7) and tongue swabs (difference, 18.3 percentage points; 95% CI, 12.0 to 24.7). The test showed diagnostic accuracy that was consistent with World Health Organization (WHO) accuracy targets for near-point-of-care tuberculosis diagnostics (≥85% sensitivity for sputum and ≥75% for nonsputum and ≥98% specificity for both). The median score on the system usability scale (range, 0 to 100, with higher scores indicating better perceived usability) was 75 (interquartile range, 65 to 80), which indicated good usability. No adverse events related to the index test were reported.

CONCLUSIONS

MiniDock MTB met WHO targets for diagnostic accuracy and usability for tuberculosis detection across diverse clinical settings. (Funded by the National Institutes of Health and others; Rapid Research in Diagnostics Development for TB Network and Assessing Diagnostics at Point-of-Care for Tuberculosis ClinicalTrials.gov numbers, NCT04923958 and NCT05941052.).

Для цитирования: Yerlikaya Seda, Chirwa Masuzyo, Ajide Bukola, Castro Maria Del Mar, Ha Huy, Kato-Maeda Midori, Kisakye Esther, Marcelo Danaida, Mochizuki Tessa, Rockman Loren, Steadman Amy, Thangakunam Balamugesh, Bimba John Samson, Christopher Devasahayam J, Muyoyeta Monde, Phan Ha, Theron Grant, Yu Charles, Kremer Kristin, Phillips Patrick P J, Nahid Payam, Denkinger Claudia M, Cattamanchi Adithya, Andama Alfred, R2D2 TB Network and SMART4TB Consortia. Pulmonary Tuberculosis Detection with MiniDock MTB Using Swab Samples.. The New England journal of medicine. 2026. DOI: 10.1056/nejmoa2509761.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.