MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2460/ajvr.68.8.858

Медицинская библиотека · American journal of veterinary research · 2007

Effect of computed tomography display window and image plane on diagnostic certainty for characteristics of dysplastic elbow joints in dogs.

Tromblee Tonya C, Jones Jeryl C, Bahr Anne M, Shires Peter K, Aref Susanne

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To test the effects of computed tomography (CT) image plane and window settings on diagnostic certainty for CT characteristics associated with dysplastic elbow joints (elbow joint dysplasia) in dogs and to provide optimal display guidelines for these CT characteristics.

SAMPLE POPULATION: CT images of 50 dysplastic elbow joints from 49 lame dogs and 10 elbow joints from 5 sound dogs.

PROCEDURES: CT image data were obtained in transverse, sagittal, and dorsal planes. Each plane was examined by use of 3 Hounsfield unit (HU) window settings. Two veterinary radiologists independently evaluated sets of CT images for evidence of 7 CT characteristics. Effect of elbow joint status, image plane, and window settings on diagnostic certainty for these CT characteristics was tested by use of a visual analogue scale.

RESULTS

Diagnostic certainty for abnormalities of the medial coronoid process (MCP) and radial incisure was highest in the transverse plane, subchondral defects or sclerosis of the trochlea humeri was highest in the dorsal plane, and joint incongruity was highest in the sagittal plane. Certainty for hypoattenuating subchondral defects or fissures was highest at 2,500 or 3,500 HUs, whereas certainty for subchondral sclerosis was highest at 1,500 HUs and lowest at 3,500 HUs.

CONCLUSIONS AND CLINICAL RELEVANCE: Diagnostic certainty for CT characteristics of elbow joint dysplasia in dogs was affected by image display variables. Diagnostic certainty for altered subchondral bone density was primarily influenced by window settings, whereas structural MCP abnormalities and joint incongruity were influenced most by image plane.

Для цитирования: Tromblee Tonya C, Jones Jeryl C, Bahr Anne M, Shires Peter K, Aref Susanne. Effect of computed tomography display window and image plane on diagnostic certainty for characteristics of dysplastic elbow joints in dogs.. American journal of veterinary research. 2007. DOI: 10.2460/ajvr.68.8.858.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.