MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1757-7861.2012.00175.x

Медицинская библиотека · Orthopaedic surgery · 2012

Factors influencing segmental lumbar lordosis after lateral transpsoas interbody fusion.

Kepler Christopher K, Huang Russel C, Sharma Amit K, Meredith Dennis S, Metitiri Ochuko, Sama Andrew A, Girardi Federico P, Cammisa Frank P

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

Although contributions to sagittal alignment have been characterized for anterior, posterior and transforaminal lumbar interbody fusion, sagittal alignment after lateral transpsoas interbody fusion (LTIF) has not yet been characterized. This study examined the ability of LTIF to restore lumbar lordosis and identified factors associated with change in sagittal alignment.

METHODS

Twenty-nine patients and 67 levels were studied. Segmental lordosis, anterior-posterior cage position, and cage obliquity were measured on preoperative and postoperative radiographs and CT scans. Change in sagittal alignment was analyzed with respect to demographic information and measures of cage position and obliquity to identify factors associated with segmental alignment change.

RESULTS

Mean lordosis increased 3.7° at instrumented segments, increasing from 4.1° preoperatively to 7.8° postoperatively. Although increases at each level were significant, there were no significant differences between levels. Lordosis increase was inversely-associated with preoperative lordosis; levels with the least preoperative lordosis gained the most lordosis. Cage obliquity and height were not significantly associated with lordosis change. Anterior cage placement resulted in the largest lordosis gain (+7.4°/level) while posterior placement was prokyphotic (-1.2°/level). There were no significant associations with age, sex or body mass index.

CONCLUSION

Anteroposterior cage placement is an important intraoperative determinant of postoperative alignment; anterior placement results in greater lordosis while middle/posterior placement has a minimal effect on sagittal alignment.

Для цитирования: Kepler Christopher K, Huang Russel C, Sharma Amit K, Meredith Dennis S, Metitiri Ochuko, Sama Andrew A, Girardi Federico P, Cammisa Frank P. Factors influencing segmental lumbar lordosis after lateral transpsoas interbody fusion.. Orthopaedic surgery. 2012. DOI: 10.1111/j.1757-7861.2012.00175.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.