INTRODUCTION
Anterior tibial intercondylar eminence fractures (ATIEF) of the knee are rare in children. They are associated with prefracture intraligamental distention of the anterior cruciate ligament (ACL).
OBJECTIVE
The objective of this study was to evaluate the subjective and objective clinical results of an arthroscopic surgical technique by suture-fixation of the fracture and tensioning of the ACL through hollowing of the tibial footprint.
HYPOTHESIS: Suture-tensioning of ATIEF arthroscopically helps to achieve treatment objectives by leaving the knee joint free of any hardware.
MATERIALS AND
METHODS
This single-operator monocentric retrospective study involved twenty children operated on over a period of 2-years and 10 months, from March 2013, and with a minimum of one-year follow-up. Surgery was indicated for Stage II to IV fractures according to the Meyers and McKeever classification. Type I fractures were excluded. Seventeen out of 20 patients were reviewed. The median age was 12 years at the time of surgery and the mean follow-up was 28 months. The fractures were 5 of stage II, 9 of III and 3 of IV. The scores of Lysholm, objective and subjective IKDC were collected. Residual objective laxity was measured using the GNRB arthrometer at 150N. A standard X-ray evaluation permitted detection of possible growth disorders.
RESULTS
At 28 months of mean follow-up, the mean scores of Lysholm and subjective IKDC were 99 (95; 100) and 97 (92; 100), respectively. As for the objective IKDC, 14 knees were rated A and 3 were rated B. The mean differential residual laxity via GNRB was 0.94mm (0; 2.4). No radiological growth disorder was observed at the last follow-up.
CONCLUSION
The ACL suture-tensioning technique is simple and reliable. It also preserves the joint of the adult to remain free of any residual hardware.
LEVEL OF EVIDENCE: IV; retrospective cohort study.