MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/evj.13960

Медицинская библиотека · Equine veterinary journal · 2023

Composition, architecture and biomechanical properties of articular cartilage in differently loaded areas of the equine stifle.

Fugazzola Maria, Nissinen Mikko T, Jäntti Jiri, Tuppurainen Juuso, Plomp Saskia, Te Moller Nikae, Mäkelä Janne T A, van Weeren Rene

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Strategies for articular cartilage repair need to take into account topographical differences in tissue composition and architecture to achieve durable functional outcome. These have not yet been investigated in the equine stifle.

OBJECTIVES

To analyse the biochemical composition and architecture of three differently loaded areas of the equine stifle. We hypothesise that site differences correlate with the biomechanical characteristics of the cartilage.

STUDY

DESIGN

Ex vivo study.

METHODS

Thirty osteochondral plugs per location were harvested from the lateral trochlear ridge (LTR), the distal intertrochlear groove (DITG) and the medial femoral condyle (MFC). These underwent biochemical, biomechanical and structural analysis. A linear mixed model with location as a fixed factor and horse as a random factor was applied, followed by pair-wise comparisons of estimated means with false discovery rate correction, to test for differences between locations. Correlations between biochemical and biomechanical parameters were tested using Spearman's correlation coefficient.

RESULTS

Glycosaminoglycan content was different between all sites (estimated mean [95% confidence interval (CI)] for LTR 75.4 [64.5, 88.2], for intercondylar notch (ICN) 37.3 [31.9, 43.6], for MFC 93.7 [80.1109.6] μg/mg dry weight), as were equilibrium modulus (LTR2.20 [1.96, 2.46], ICN0.48 [0.37, 0.6], MFC1.36 [1.17, 1.56] MPa), dynamic modulus (LTR7.33 [6.54, 8.17], ICN4.38 [3.77, 5.03], MFC5.62 [4.93, 6.36] MPa) and viscosity (LTR7.49 [6.76, 8.26], ICN16.99 [15.88, 18.14], MFC8.7 [7.91,9.5]°). The two weightbearing areas (LTR and MCF) and the non-weightbearing area (ICN) differed in collagen content (LTR 139 [127, 152], ICN176[162, 191], MFC 127[115, 139] μg/mg dry weight), parallelism index and angle of collagen fibres. The strongest correlations were between proteoglycan content and equilibrium modulus (r: 0.642; p: 0.001), dynamic modulus (r: 0.554; p < 0.001) and phase shift (r: -0.675; p < 0.001), and between collagen orientation angle and equilibrium modulus (r: -0.612; p < 0.001), dynamic modulus (r: -0.424; p < 0.001) and phase shift (r: 0.609; p < 0.001).

MAIN LIMITATIONS: Only a single sample per location was analysed.

CONCLUSIONS

There were significant differences in cartilage biochemical composition, biomechanics and architecture between the three differently loaded sites. The biochemical and structural composition correlated with the mechanical characteristics. These differences need to be acknowledged by designing cartilage repair strategies.

Для цитирования: Fugazzola Maria, Nissinen Mikko T, Jäntti Jiri, Tuppurainen Juuso, Plomp Saskia, Te Moller Nikae, Mäkelä Janne T A, van Weeren Rene. Composition, architecture and biomechanical properties of articular cartilage in differently loaded areas of the equine stifle.. Equine veterinary journal. 2023. DOI: 10.1111/evj.13960.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.