MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41598-023-35706-3

Медицинская библиотека · Scientific reports · 2023

Biomechanical performance of a novel light-curable bone fixation technique.

Schwarzenberg Peter, Colding-Rasmussen Thomas, Hutchinson Daniel J, Mischler Dominic, Horstmann Peter, Petersen Michael Mørk, Jacobsen Stine, Pastor Tatjana, Malkoch Michael, Wong Christian, Varga Peter

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Traumatic bone fractures are often debilitating injuries that may require surgical fixation to ensure sufficient healing. Currently, the most frequently used osteosynthesis materials are metal-based; however, in certain cases, such as complex comminuted osteoporotic fractures, they may not provide the best solution due to their rigid and non-customizable nature. In phalanx fractures in particular, metal plates have been shown to induce joint stiffness and soft tissue adhesions. A new osteosynthesis method using a light curable polymer composite has been developed. This method has demonstrated itself to be a versatile solution that can be shaped by surgeons in situ and has been shown to induce no soft tissue adhesions. In this study, the biomechanical performance of AdhFix was compared to conventional metal plates. The osteosyntheses were tested in seven different groups with varying loading modality (bending and torsion), osteotomy gap size, and fixation type and size in a sheep phalanx model. AdhFix demonstrated statistically higher stiffnesses in torsion (64.64 ± 9.27 and 114.08 ± 20.98 Nmm/° vs. 33.88 ± 3.10 Nmm/°) and in reduced fractures in bending (13.70 ± 2.75 Nm/mm vs. 8.69 ± 1.16 Nmm/°), while the metal plates were stiffer in unreduced fractures (7.44 ± 1.75 Nm/mm vs. 2.70 ± 0.72 Nmm/°). The metal plates withstood equivalent or significantly higher torques in torsion (534.28 ± 25.74 Nmm vs. 614.10 ± 118.44 and 414.82 ± 70.98 Nmm) and significantly higher bending moments (19.51 ± 2.24 and 22.72 ± 2.68 Nm vs. 5.38 ± 0.73 and 1.22 ± 0.30 Nm). This study illustrated that the AdhFix platform is a viable, customizable solution that is comparable to the mechanical properties of traditional metal plates within the range of physiological loading values reported in literature.

Для цитирования: Schwarzenberg Peter, Colding-Rasmussen Thomas, Hutchinson Daniel J, Mischler Dominic, Horstmann Peter, Petersen Michael Mørk, Jacobsen Stine, Pastor Tatjana, Malkoch Michael, Wong Christian, Varga Peter. Biomechanical performance of a novel light-curable bone fixation technique.. Scientific reports. 2023. DOI: 10.1038/s41598-023-35706-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.