MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1121/10.0028173

Медицинская библиотека · The Journal of the Acoustical Society of America · 2024

Cortical bone plate properties assessment using inversion of axially transmitted low frequency ultrasonic guided waves.

Chaboty Aubin, Nguyen Vu-Hieu, Haiat Guillaume, Bélanger Pierre

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Over the past few decades, early osteoporosis detection using ultrasonic bone quality evaluation has gained prominence. Specifically, various studies focused on axial transmission using ultrasonic guided waves and have highlighted this technique's sensitivity to intrinsic properties of long cortical bones. This work aims to demonstrate the potential of low-frequency ultrasonic guided waves to infer the properties of the bone inside which they are propagating. A proprietary ultrasonic transducer, tailored to transmit ultrasonic guided waves under 500 kHz, was used for the data collection. The gathered data underwent two-dimensional fast Fourier transform processing to extract experimental dispersion curves. The proposed inversion scheme compares experimental dispersion curves with simulated dispersion curves calculated through the semi-analytical iso-geometric analysis (SAIGA) method. The numerical model integrates a bone phantom plate coupled with a soft tissue layer on its top surface, mimicking the experimental bone phantom plates. Subsequently, the mechanical properties of the bone phantom plates were estimated by reducing the misfit between the experimental and simulated dispersion curves. This inversion leaned heavily on the dispersive trajectories and amplitudes of ultrasonic guided wave modes. Results indicate a marginal discrepancy under 5% between the mechanical properties ascertained using the SAIGA-based inversion and those measured using bulk wave pulse-echo measurements.

Для цитирования: Chaboty Aubin, Nguyen Vu-Hieu, Haiat Guillaume, Bélanger Pierre. Cortical bone plate properties assessment using inversion of axially transmitted low frequency ultrasonic guided waves.. The Journal of the Acoustical Society of America. 2024. DOI: 10.1121/10.0028173.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.