MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/s23073487

Медицинская библиотека · Sensors (Basel, Switzerland) · 2023

Assessment of Passive Upper Limb Stiffness and Its Function in Post-Stroke Individuals Wearing an Inertial Sensor during the Pendulum Test.

de Lima Milene Soares Nogueira, Dos Santos Couto Paz Clarissa Cardoso, Ribeiro Thais Gontijo, Fachin-Martins Emerson

СтатьяПеревод в очереди

Аннотация

This article proposes the evaluation of the passive movement of the affected elbow during the pendulum test in people with stroke and its correlation with the main clinical scales (Modified Ashworth Scale, Motor Activity Log, and Fulg Meyer). An inertial sensor was attached to the forearm of seven subjects, who then passively flexed and extended the elbow. Joint angles and variables that indicate viscoelastic properties, stiffness (K), damping (B), E1 amp, F1 amp, and relaxation indices were collected. The results show that the FM scale is significantly correlated with the natural frequency (p = 0.024). The MAL amount-of-use score correlates with the natural frequency (p = 0.024). The variables E1 amp, F1 amp, RI, and ERI are not correlated with the clinical scales, but they correlate with each other; the variable E1 amp correlates with F1 amp (p = 0.024) and RI (p = 0.024), while F1 amp correlates with ERI (p = 0.024). There was also a correlation between the natural frequency and K (r = 0.96, p = 0.003). Non-linear results were found for the properties of the elbow joint during the pendulum test, which may be due to the presence of neural and non-neural factors. These results may serve as a reference for future studies if alternative scales do not provide an accurate reflection.

Для цитирования: de Lima Milene Soares Nogueira, Dos Santos Couto Paz Clarissa Cardoso, Ribeiro Thais Gontijo, Fachin-Martins Emerson. Assessment of Passive Upper Limb Stiffness and Its Function in Post-Stroke Individuals Wearing an Inertial Sensor during the Pendulum Test.. Sensors (Basel, Switzerland). 2023. DOI: 10.3390/s23073487.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.