Anatomic Factors Associated With Osteochondral Allograft Matching for Trochlear Cartilage Defects: A Computer-Simulation Study.

Dandu Navya, Horner Nolan S, Trasolini Nicholas A, Hevesi Mario, Cregar William M, Inoue Nozomu, Yanke Adam B

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Articular step-off between the donor and recipient in osteochondral allograft transplant has been shown to alter contact pressures. Currently, commercial allograft donor selection is primarily based on simple anatomic parameters such as trochlear length, trochlear width, and tibial width.

PURPOSE: To identify anatomic factors associated with optimal graft matching by using a 3-dimensional simulation model.

STUDY

DESIGN

Descriptive laboratory study.

METHODS

Computed tomography images of 10 cadaveric trochlear specimens were obtained to generate 3-dimensional models. Circular defects were created virtually in the recipient trochleae at both superolateral (18.0 mm and 22.5 mm) and central (18.0 mm, 22.5 mm, 30.0 mm) locations. The donor models were virtually projected onto the defect models, and the most optimal graft from any location of the donor specimen was selected. Cartilage incongruity, subchondral bone incongruity, and peripheral articular step-off were calculated for each graft-defect combination. Linear regression models were generated to identify predictors of incongruity, step-off, and the effect of sulcus and sagittal angle mismatch. Akaike information criterion-driven stepwise regression models were generated to identify multivariate predictors.

RESULTS

Ideal matches were found for 100% of superolateral defects but for only 15% to 53% of central defects, depending on the defect size. Multivariate stepwise regression identified laterality (odds ratio [OR], 0.54; P = .081), sulcus angle (OR, 0.79; P < .001), sagittal angle (OR, 0.83; P = .001), lateral radius of curvature (OR, 0.81; P < .001), and medial facet width (OR, 0.86; P = .155) as predictors of ideal graft matching. In central defects with proud grafts, increasing sagittal angle and sulcus angle resulted in significantly (P < .001) increased articular step-off, which became sequentially larger with defect size.

CONCLUSION

Sagittal angle, sulcus angle, and lateral radius of curvature mismatch should be used to determine optimal donor allografts, especially in the setting of large (30-mm) central defects. Increasing sulcus angle and sagittal angle mismatch correlated with increasing step-off in proud grafts, whereas sulcus angle and sagittal angle inconsistently correlated with step-off in recessed grafts.

CLINICAL RELEVANCE: Additional descriptive trochlear measurements should be incorporated into the algorithm for donor selection. These findings can be used to identify acceptable mismatch parameters.

Для цитирования: Dandu Navya, Horner Nolan S, Trasolini Nicholas A, Hevesi Mario, Cregar William M, Inoue Nozomu, Yanke Adam B. Anatomic Factors Associated With Osteochondral Allograft Matching for Trochlear Cartilage Defects: A Computer-Simulation Study.. The American journal of sports medicine. 2022. DOI: 10.1177/03635465221121586.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.