m+Medelevator.RU
← Поиск публикаций
Revista da Associacao Medica Brasileira (1992) · 2018

Cobalt chromium-Titanium rods versus Titanium-Titanium rods for treatment of adolescent idiopathic scoliosis; which type of rod has better postoperative outcomes?

Сравнительное исследованиеСтатьяРандомизированное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Etemadifar Mohammad Reza, Andalib Ali, Rahimian Abbas, Nodushan Seyed Mohamad Hossein Tabatabaei

Аннотация

OBJECTIVE: Compare the outcome of spinal deformity correction between Ti-Ti and CrCo-Ti rods for the treatment of spinal Adolescent Idiopathic Scoliosis (AIS) using rods mentioned with all pedicle screws and translation technique.

METHOD: 59 patients operated for spinal deformity (Lenke 1 or 2) AIS. The patients were divided into two groups by random allocation using Ti-Ti rods (n = 29) and CrCo-Ti rods (n = 30) and the alone difference among them in the surgical procedure was rod material (Ti-Ti or CrCo-Ti rods) and finally, radiological outcomes were compared preoperatively, postoperatively and at last follow-up for 12 months.

RESULTS: Patients' main curve correction after surgical procedure regardless type of rod was 48.95±11.04 (13-75) degree. Success rate of spinal deformity correction following surgical procedure regardless of type of administered rod was 86.76 ± 11.30 percent (62.5-100%). Mean of deformity correction rate was 91.49±10.67% using CrCo-Ti rods versus 81.86±9.88% using Ti-Ti rods (P-value=0.01). Angle change was 3.29±6.60 for kyphosis angle and 0.59±7.76 for lordosis angle. Rate of main curve correction was not significantly different considering patients' gender (P-value0.657). Main curve correction success rate was in association with patients' age and type of rod (P-value=0.054, r=-1.863 and P-value=0.001, r=8.865 respectively).

CONCLUSION: CrCo-Ti rods have the ability to produce higher correction rates in AIS compared to Ti-Ti rod of the same diameter. CrCo-Ti rods provide significant and stable spinal correction, especially in correction of main curve. This rate was associated with patients' age and type of rod administered but not gender.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты