MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.clinbiomech.2024.106278

Медицинская библиотека · Clinical biomechanics (Bristol, Avon) · 2024

Biomechanical role of bone grafting for calcaneal fracture fixation in the presence of bone defect: A finite element analysis.

Su Zhihao, Ding Ming, Zhu Ning, Cheung James Chung-Wai, Wong Duo Wai-Chi, Sun Wanju, Ni Ming

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

The purpose of this study was to compare the biomechanical stress and stability of calcaneal fixations with and without bone defect, before and after bone grafting, through a computational approach.

METHODS

A finite element model of foot-ankle complex was reconstructed, impoverished with a Sanders III calcaneal fracture without bone defect and with moderate and severe bone defects. Plate fixations with and without bone grafting were introduced with walking stance simulated. The stress and fragment displacement of the calcaneus were evaluated.

FINDINGS: Moderate and severe defect increased the calcaneus stress by 16.11% and 32.51%, respectively and subsequently decreased by 10.76% and 20.78% after bone grafting. The total displacement was increased by 3.99% and 24.26%, respectively by moderate and severe defect, while that of posterior joint facet displacement was 86.66% and 104.44%. The former was decreased by 25.73% and 35.96% after grafting, while that of the latter was reduced by 88.09% and 84.78% for moderate and severe defect, respectively.

INTERPRETATION: Our finite element prediction supported that bone grafting for fixation could enhance the stability and reduce the risk of secondary stress fracture in cases of bone defect in calcaneal fracture.

Для цитирования: Su Zhihao, Ding Ming, Zhu Ning, Cheung James Chung-Wai, Wong Duo Wai-Chi, Sun Wanju, Ni Ming. Biomechanical role of bone grafting for calcaneal fracture fixation in the presence of bone defect: A finite element analysis.. Clinical biomechanics (Bristol, Avon). 2024. DOI: 10.1016/j.clinbiomech.2024.106278.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.