MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1109/jbhi.2024.3360102

Медицинская библиотека · IEEE journal of biomedical and health informatics · 2024

Anatomical Prior and Inter-Slice Consistency for Semi-Supervised Vertebral Structure Detection in 3D Ultrasound Volume.

Zeng Hongye, Zhou Kang, Ge Songhan, Gao Yuchong, Zhao Jianhao, Gao Shenghua, Zheng Rui

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Three-dimensional (3D) ultrasound imaging technique has been applied for scoliosis assessment, but the current assessment method only uses coronal projection images and cannot illustrate the 3D deformity and vertebra rotation. The vertebra detection is essential to reveal 3D spine information, but the detection task is challenging due to complex data and limited annotations. We propose VertMatch to detect vertebral structures in 3D ultrasound volume containing a detector and classifier. The detector network finds the potential positions of structures on transverse slice globally, and then the local patches are cropped based on detected positions. The classifier is used to distinguish whether the patches contain real vertebral structures and screen the predicted positions from the detector. VertMatch utilizes unlabeled data in a semi-supervised manner, and we develop two novel techniques for semi-supervised learning: 1) anatomical prior is used to acquire high-quality pseudo labels; 2) inter-slice consistency is used to utilize more unlabeled data by inputting multiple adjacent slices. Experimental results demonstrate that VertMatch can detect vertebra accurately in ultrasound volume and outperforms state-of-the-art methods. Moreover, VertMatch is also validated in automatic spinous process angle measurement on forty subjects with scoliosis, and the results illustrate that it can be a promising approach for the 3D assessment of scoliosis.

Для цитирования: Zeng Hongye, Zhou Kang, Ge Songhan, Gao Yuchong, Zhao Jianhao, Gao Shenghua, Zheng Rui. Anatomical Prior and Inter-Slice Consistency for Semi-Supervised Vertebral Structure Detection in 3D Ultrasound Volume.. IEEE journal of biomedical and health informatics. 2024. DOI: 10.1109/jbhi.2024.3360102.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.