[Clinical relevance of multislice CT of the spine after osteosynthesis].

Lorenzen M, Wedegärtner U, Weber C, Petersen J P, Adam G, Lorenzen J

Сравнительное исследованиеОценочное исследованиеСтатьяПеревод в очереди

Аннотация

PURPOSE: To examine the clinical relevance of multislice CT (MSCT) scans in postoperative checks of the spine after osteosynthesis.

MATERIAL AND

METHODS

The results of x-rays (apical lateral) in 30 patients having spinal surgery involving osteosynthesis (5 x metastasis, 20 x fractures, 3 x spondylolisthesis, 2 x scoliosis) were correlated to those of MSCT (140 kV, 200 mAs, collimation 4 x 1 mm, pitch 0.75; VolumeZoom, Siemens, Erlangen, Germany) with multiplanar reconstruction. Two radiologists independently checked the conventional x-ray and multislice CT scans for anatomical positioning, damage of osteosynthetic material, and intraspinal dislocation of bone fragments.

RESULTS

By correlating conventional spinal x-rays with MSCT, additional diagnostic information was gained. In 9 of 30 patients MSCT revealed the extraosseal location of a screw tip (x-ray, 5/30), in 8/30 patients a narrowing of the spinal canal by osteosynthetic material was detected in MSCT (x-ray, 4/30), in 2/30 patients osteal fragments were detected in the vertebral canal by MSCT (x-ray, 0/30). In MSCT and in conventional x-ray a fracture of the osteosynthesis was correctly diagnosed in 3 patients. One patient underwent corrective surgery for dislocated osteosynthetic material, which was solely diagnosed with MSCT.

CONCLUSION

Due to the high degree of additional diagnostic information MSCT seems to be the method of choice for postoperative spinal surgery involving osteosynthesis.

Для цитирования: Lorenzen M, Wedegärtner U, Weber C, Petersen J P, Adam G, Lorenzen J. [Clinical relevance of multislice CT of the spine after osteosynthesis].. RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin. 2005. DOI: 10.1055/s-2005-858555.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.