An experimental in vitro biomechanical study was conducted on human cadaveric spines to evaluate the motion segment (C4-C5) and global subaxial cervical spine motion after placement of a cervical arthroplasty device (Altia TDI,Amedica, Salt Lake City, UT) as compared to both the intact spine and a single-level fusion. Six specimens (C2-C7) were tested in flexion/extension, lateral bending, and axial rotation under a +/- 1.5 Nm moment with a 100 N axial follower load. Following the intact spine was tested; the cervical arthroplasty device was implanted at C4-C5 and tested. Then, a fusion using lateral mass fixation and an anterior plate was simulated and tested. Stiffness and range of motion (ROM) data were calculated. The ROM of the C4-C5 motion segment with the arthroplasty device was similar to that of the intact spine in flexion/extension and slightly less in lateral bending and rotation, while the fusion construct allowed significantly less motion in all directions. The fusion construct caused broader effects of increasing motion in the remaining segments of the subaxial cervical spine, whereas the TDI did not alter the adjacent and remote motion segments. The fusion construct was also far stiffer in all motion planes than the intact motion segment and the TDI, while the artificial disc treated level was slightly stiffer than the intact segment. The Altia TDI allows for a magnitude of motion similar to that of the intact spine at the treated and adjacent levels in the in vitro setting.

Для цитирования: Finn Michael A, Brodke Darrel S, Daubs Michael, Patel Alpesh, Bachus Kent N. Local and global subaxial cervical spine biomechanics after single-level fusion or cervical arthroplasty.. European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society. 2009. DOI: 10.1007/s00586-009-1085-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.