MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1109/embc53108.2024.10782556

Медицинская библиотека · Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2024

Design of custom splint for distal radius fractures in Children through Generative design, Finite Element analysis and 3D Printing.

Lozano Aguilar Andrea Jimena, Leyla Postigo Yauce Rosmy, Sifuentes Midori Sanchez

СтатьяПеревод в очереди

Аннотация

In this article, we investigate the effectiveness of parametric design in Fusion 360, guided by generative design studies and complemented with finite element analysis (FEA) simulations, to develop custom splints through 3D printing. Our goal is to provide a more comfortable and functional alternative to conventional splints, particularly in the treatment of pediatric fractures in the distal radius, addressing limitations associated with traditional options. Additionally, we aim to fill the information gap regarding the use of 3D-printed splints for fractures, specifically through the application of generative design technologies in this context. Based on the obtained results, a custom splint with specific dimensions, weight (103g), and detailed strength has been designed. The splint has demonstrated robustness and safety, efficiently supporting specific loads. These achievements position the splint as a promising option for treating pediatric distal radius fractures. This study lays the groundwork for future research and clinical applications.

Для цитирования: Lozano Aguilar Andrea Jimena, Leyla Postigo Yauce Rosmy, Sifuentes Midori Sanchez. Design of custom splint for distal radius fractures in Children through Generative design, Finite Element analysis and 3D Printing.. Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference. 2024. DOI: 10.1109/embc53108.2024.10782556.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.