MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/10255842.2022.2115293

Медицинская библиотека · Computer methods in biomechanics and biomedical engineering · 2022

A comparison of intervertebral ligament properties utilized in a thoracic spine functional unit through kinematic evaluation.

Polanco Michael, Ringleb Stacie, Audette Michel, Kakar Rumit, Bawab Sebastian

СтатьяПеревод в очереди

Аннотация

Ligament properties in the literature are variable, yet scarce, but needed to calibrate computational models for spine clinical research applications. A comparison of ligament stiffness properties and their effect on the kinematic behavior of a thoracic functional spinal unit (FSU) is examined in this paper. Six unique ligament property sets were utilized within a volumetric T7-T8 finite element (FE) model developed using computer-aided design (CAD) spinal geometry. A 7.5 Nm moment was applied along three anatomical planes both with and without costovertebral (CV) joints present. Range of Motion (RoM) was assessed for each property set and compared to published experimental data. Intact and serial ligament removal procedures were implemented in accordance with experimental protocol. The variance in both kinematic behavior and comparability with experimental data among property sets emphasizes the role nonlinear characterization plays in determining proper kinematic behavior in spinal FE models. Additionally, a decrease in RoM variation among property sets was exhibited when the model setup incorporated the CV joint. With proper assessment of the source and size of each ligament, the material properties considered here could be expanded and justified for implementation into thoracic spine clinical studies.

Для цитирования: Polanco Michael, Ringleb Stacie, Audette Michel, Kakar Rumit, Bawab Sebastian. A comparison of intervertebral ligament properties utilized in a thoracic spine functional unit through kinematic evaluation.. Computer methods in biomechanics and biomedical engineering. 2022. DOI: 10.1080/10255842.2022.2115293.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.