MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · The Iowa orthopaedic journal · 2018

Total Hip Arthroplasty for Crowe Type IV Developmental Dysplasia of the Hip Using a Titanium Mesh Cup and Subtrochanteric Femoral Osteotomy.

Chen Mengcun, Gittings Daniel J, Yang Shuhua, Liu Xianzhe

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Treatment of Crowe IV developmental dysplasia of the hip (DDH) with total hip arthroplasty (THA) reconstructs the true acetabulum, which improves hip biomechanics and function. However, restoration of the native acetabulum may lead to limb lengthening and traction neuropraxia. The purpose of this study is to describe the short term results of a retrospectively reviewed series of patients with Crowe IV DDH treated with THA using a titanium mesh cup, cemented liner, and subtrochanteric femoral shortening osteotomy.

METHODS

Eighteen patients (21 hips) with an average age of 47 years (age range: 28-61 years) with Crowe IV DDH underwent reconstructive THA and subtrochanteric femoral shortening osteotomy between September 2005 and February 2014. Follow up was assessed at 1, 3, 6, 9, and 12 months post operatively and then annually after the first year. The average follow up was 3.5 years (range 0.5-9 years). At each follow up visit, radiographs were used to assess for osteolysis and subsidence. Preoperative and postoperative patient reported outcomes including Harris Hip Score and Modified Merle d'Aubigne Hip Score were compared.

RESULTS

At the minimum 6 month follow up, all radiographic assessments showed no signs of osteolysis or subsidence of the implants. Both the Harris Hip Score and Modified Merle d'Aubigne Hip Score improved from preoperative assessments (p<0.05). Three patients developed symptoms of sciatic nerve neuropraxia that subsequently resolved.

CONCLUSION

THA of Crowe IV DDH by reconstructing the acetabulum with bone graft, a titanium mesh cup, cemented liner, and subtrochanteric femoral shortening osteotomy demonstrated no osteolysis or subsidence and improved function with a low incidence of sciatic nerve palsy at short term follow up.Level of evidence: IV.

Для цитирования: Chen Mengcun, Gittings Daniel J, Yang Shuhua, Liu Xianzhe. Total Hip Arthroplasty for Crowe Type IV Developmental Dysplasia of the Hip Using a Titanium Mesh Cup and Subtrochanteric Femoral Osteotomy.. The Iowa orthopaedic journal. 2018.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.