Standardized Measurement of Muscle Strength and Physical Performance for Sarcopenia: An Expert-Based Delphi Consensus.

Lim Seung-Kyu, Beom Jaewon, Lee Sang Yoon, Min Kyunghoon, Byun Seong-Eun, Cha Yonghan, Choi Jun Hwan, Choi Jung-Yeon, Han Jae-Young, Jang Hak-Chul, Jung Hee-Won, Kim Kwang-Il, Kim Younji, Kim Young-Sang, Lee Jong Hwa, Lee Jong In, Lee Seung Yeol, Lim Kil-Byung, Oh Bumjo, Park Sae-Jong, Shim Ga Yang, Song Wook, Won Chang Won, Yoo Jun-Il, Yoo Seung Don, Lim Jae-Young

СтатьяПоддержка исследования: вне правительства СШАConsensus StatementПеревод в очереди

Аннотация

BACKGROUND

Despite updated sarcopenia guidelines, inconsistent protocols still cause clinical confusion and may compromise diagnostic and outcome accuracy. This Delphi study aimed to establish expert consensus to support the standardization of muscle strength and physical performance assessments for sarcopenia.

METHODS

A two-round modified Delphi study was conducted with 26 experts in geriatrics and sarcopenia. Participants completed two rounds of anonymous questionnaires evaluating 39 items across seven domains using a nine-point Likert scale or choice-based questions. Consensus was defined as ≥75% agreement.

RESULTS

In total, 27 of 38 statements (71.1%) reached consensus across two rounds Experts supported further standardization of assessments in alignment with the Asian and Korean Working Group on Sarcopenia (AWGS and KWGS) guidelines. For handgrip strength, consensus was achieved on using both mechanical and hydraulic dynamometers, hydraulic protocols, value selection, measurement time, and positioning, but not on mechanical protocols, repetitions, recovery intervals, repetitions, or unified cutoff values. For calf circumference, consensus was reached on measurement position, method, and value selection, but not on guideline application. In gait speed assessment, agreement was reached on speed, repetitions, assistive device use, and equipment type, but not on value selection, distance, acceleration/deceleration phases, or device interchangeability. For the 400-m walk test, the KWGS guideline and speed were endorsed. Chair stand test (CST) and Timed up-and-go (TUG) test reached consensus on armrest use, value selection, and repetitions, but not on seat height, (CST), or speed (TUG).

CONCLUSION

This study highlights areas of agreement and ongoing uncertainty, supporting future standardization efforts sarcopenia assessment methods.

Для цитирования: Lim Seung-Kyu, Beom Jaewon, Lee Sang Yoon, Min Kyunghoon, Byun Seong-Eun, Cha Yonghan, Choi Jun Hwan, Choi Jung-Yeon, Han Jae-Young, Jang Hak-Chul, Jung Hee-Won, Kim Kwang-Il, Kim Younji, Kim Young-Sang, Lee Jong Hwa, Lee Jong In, Lee Seung Yeol, Lim Kil-Byung, Oh Bumjo, Park Sae-Jong, Shim Ga Yang, Song Wook, Won Chang Won, Yoo Jun-Il, Yoo Seung Don, Lim Jae-Young. Standardized Measurement of Muscle Strength and Physical Performance for Sarcopenia: An Expert-Based Delphi Consensus.. Annals of geriatric medicine and research. 2025. DOI: 10.4235/agmr.25.0070.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.