MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s13018-024-04606-1

Медицинская библиотека · Journal of orthopaedic surgery and research · 2024

Biomechanical characteristics of Sanders type II and III calcaneal fractures fixed by open reduction and internal fixation and percutaneous minimally invasive fixation.

Ren Wu, Zhang Kailu, Zhao Ziya, Zhang Xueling, Lin Fei, Li Yawei, Bao Ke, Yang Jun, Chang Jinlong, Li Jia

СтатьяПеревод в очереди

Аннотация

BACKGROUND

This work investigated the differences in the biomechanical properties of open reduction and internal fixation (ORIF) and percutaneous minimally invasive fixation (PMIF) for the fixation of calcaneal fractures (Sanders type II and III calcaneal fractures as examples) through finite element analysis.

METHODS

Based on CT images of the human foot and ankle, according to the principle of three-point fixation, namely the sustentaculum tali, the anterior process and the calcaneal tuberosity were fixed. Three-dimensional finite element models of Sanders type II and III calcaneal fractures fixed by ORIF and PMIF were established. The proximal surfaces of the tibia, fibula and soft tissue were constrained, and ground reaction force and Achilles tendon force loads were added to simulate balanced standing.

RESULTS

The maximum stress was 80.54, 211.59 and 113.88 MPa for the calcaneus, screws and plates in the ORIF group and 70.02 and 209.46 MPa for the calcaneus and screws in the PMIF group, respectively; the maximum displacement was 0.26, 0.21 and 0.12 mm for the calcaneus, screws and plates in the ORIF group and 0.20 and 0.14 mm for the calcaneus and screws in the PMIF group, respectively. The values obtained from the simulation were within the permissible stress and elastic deformation range of the materials used in the model, and there was no significant stress concentration. The maximum stress and displacement of the calcaneus and implants were slightly lower in the PMIF group than in the ORIF group when fixing Sanders type II and III calcaneal fractures.

CONCLUSIONS

This study may provide a reference for optimising the design of implants, the development of individualised preoperative plans and the choice of clinical surgical approach.

Для цитирования: Ren Wu, Zhang Kailu, Zhao Ziya, Zhang Xueling, Lin Fei, Li Yawei, Bao Ke, Yang Jun, Chang Jinlong, Li Jia. Biomechanical characteristics of Sanders type II and III calcaneal fractures fixed by open reduction and internal fixation and percutaneous minimally invasive fixation.. Journal of orthopaedic surgery and research. 2024. DOI: 10.1186/s13018-024-04606-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.