MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · Zhonghua wai ke za zhi [Chinese journal of surgery] · 2004

[Anterior cervical diskectomy and fusion with allograft and internal fixation].

Zhang Yong-gang, Wang Yan, Liu Zheng-sheng, Xiao Song-hua, Liu Bao-wei

Аннотация на английскомСтатьяПеревод в очереди

Аннотация

OBJECTIVE

To evaluate the effect of cylindrical titanium mesh packing cancellous allograft in the anterior cervical fusion for the cervical spondylosis with anterior titanium plate.

METHODS

Ninety-eight patients with cervical spondylosis underwent diskectomy and cancellous allograft contained in cylindrical titanium mesh enhanced by anterior titanium plate system. Sixty-four patients were followed up clinically and radiographically. The mean follow-up time was (15.2 +/- 1.7) months. JOA scores and Nurick myelopathy grading system were used for clinical assessment. Roentgenograms were analyzed to identify the stability of fused levels.

RESULTS

In all patients of 98 cases, the wounds were normally healed without acute or chronic infection. In statistical analysis of 64 patients followed up, the mean JOA scores was (11.6 +/- 1.8) preoperatively and improved to (16.0 +/- 1.2) at final follow-up (P < 0.05). And the mean Nurick grades were (2.7 +/- 0.7) and (0.7 +/- 0.8) before and after surgery respectively (P < 0.05). The X-ray films demonstrated that no meshes were found displacing or subsiding. New bone formation occurred in the back of meshes at 5 months after surgery. The final follow-up fusion rate was 95%.

CONCLUSION

The cancellous allograft impacted into titanium meshes for cervical fusion has gained excellent or good results clinically and radiographically in short term follow-up.

Для цитирования: Zhang Yong-gang, Wang Yan, Liu Zheng-sheng, Xiao Song-hua, Liu Bao-wei. [Anterior cervical diskectomy and fusion with allograft and internal fixation].. Zhonghua wai ke za zhi [Chinese journal of surgery]. 2004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.