MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/ehjci/jeac107

Медицинская библиотека · European heart journal. Cardiovascular Imaging · 2023

Histopathological validation of semi-automated myocardial scar quantification techniques for dark-blood late gadolinium enhancement magnetic resonance imaging.

Nies Hedwig M J M, Gommers Suzanne, Bijvoet Geertruida P, Heckman Luuk I B, Prinzen Frits W, Vogel Gaston, Van De Heyning Caroline M, Chiribiri Amedeo, Wildberger Joachim E, Mihl Casper, Holtackers Robert J

СтатьяПеревод в очереди

Аннотация

AIMS: To evaluate the performance of various semi-automated techniques for quantification of myocardial infarct size on both conventional bright-blood and novel dark-blood late gadolinium enhancement (LGE) images using histopathology as reference standard.

METHODS AND

RESULTS

In 13 Yorkshire pigs, reperfused myocardial infarction was experimentally induced. At 7 weeks post-infarction, both bright-blood and dark-blood LGE imaging were performed on a 1.5 T magnetic resonance scanner. Following magnetic resonance imaging (MRI), the animals were sacrificed, and histopathology was obtained. The percentage of infarcted myocardium was assessed per slice using various semi-automated scar quantification techniques, including the signal threshold vs. reference mean (STRM, using 3 to 8 SDs as threshold) and full-width at half-maximum (FWHM) methods, as well as manual contouring, for both LGE methods. Infarct size obtained by histopathology was used as reference. In total, 24 paired LGE MRI slices and histopathology samples were available for analysis. For both bright-blood and dark-blood LGE, the STRM method with a threshold of 5 SDs led to the best agreement to histopathology without significant bias (-0.23%, 95% CI [-2.99, 2.52%], P = 0.862 and -0.20%, 95% CI [-2.12, 1.72%], P = 0.831, respectively). Manual contouring significantly underestimated infarct size on bright-blood LGE (-1.57%, 95% CI [-2.96, -0.18%], P = 0.029), while manual contouring on dark-blood LGE outperformed semi-automated quantification and demonstrated the most accurate quantification in this study (-0.03%, 95% CI [-0.22, 0.16%], P = 0.760).

CONCLUSION

The signal threshold vs. reference mean method with a threshold of 5 SDs demonstrated the most accurate semi-automated quantification of infarcted myocardium, without significant bias compared to histopathology, for both conventional bright-blood and novel dark-blood LGE.

Для цитирования: Nies Hedwig M J M, Gommers Suzanne, Bijvoet Geertruida P, Heckman Luuk I B, Prinzen Frits W, Vogel Gaston, Van De Heyning Caroline M, Chiribiri Amedeo, Wildberger Joachim E, Mihl Casper, Holtackers Robert J. Histopathological validation of semi-automated myocardial scar quantification techniques for dark-blood late gadolinium enhancement magnetic resonance imaging.. European heart journal. Cardiovascular Imaging. 2023. DOI: 10.1093/ehjci/jeac107.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.