MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s43390-023-00752-4

Медицинская библиотека · Spine deformity · 2023

Quantifying a novel three-dimensional marker of scoliosis.

Arginteanu Toren, Gallagher Ryan S, Borja Austin J, Glauser Gregory, Smith Lachlan J, Pasha Saba, DeTurck Dennis, Malhotra Neil R

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Scoliosis causes abnormal spinal curvature and torsional rotation of the vertebrae and has implications for human suffering and societal cost. In differential geometry, Writhe describes three-dimensional curvature. Differential geometric quantities can inform better diagnostic metrics of scoliotic deformity. This evaluation could help physicians and researchers study scoliosis and determine treatments.

METHODS

Eight adult lumbar spine CT scans were analyzed in custom MATLAB programs to estimate Writhe and Cobb angle. Five patients exhibited scoliotic curvature, and three controls were asymptomatic. Vertebral centroids in three-dimensional space were determined, and Writhe was approximated. A T-test determined whether the affected spines had greater Writhe than the controls. Cohen's D test was used to determine effect size.

RESULTS

Writhe of scoliotic spines (5.4E-4 ± 2.7E-4) was significantly higher than non-scoliotic spines (8.2E-5 ± 1.1E-4; p = 0.008).

CONCLUSION

Writhe, a measure of curvature derived from 3D imaging, is significantly greater in scoliotic than in non-scoliotic spines. Future directions must include more subjects and examine writhe as a marker of scoliosis severity, progression, and response to treatment.

Для цитирования: Arginteanu Toren, Gallagher Ryan S, Borja Austin J, Glauser Gregory, Smith Lachlan J, Pasha Saba, DeTurck Dennis, Malhotra Neil R. Quantifying a novel three-dimensional marker of scoliosis.. Spine deformity. 2023. DOI: 10.1007/s43390-023-00752-4.