MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s13246-023-01313-9

Медицинская библиотека · Physical and engineering sciences in medicine · 2023

Weight-bearing cone-beam CT with extensive coverage for volumetric imaging in adolescent idiopathic scoliosis: system implementation and initial validation.

Liang Zejun, Xia Chunchao, Wang Qian, Chen Zengtong, Zhang Yu, Ye Chao, Zhang Yiteng, Yang Jie, Wang Hairong, Zheng Han, Du Jing, Li Zhenlin, Tang Jing

СтатьяПеревод в очереди

Аннотация

The study aimed to introduce a novel imaging method that generates large-coverage, weight-bearing, and 3D images of the whole spine. The proposed system comprises an X-ray tube, a flat panel detector, and a standing platform. The standing platform rotates the imaged subject, allowing for the acquisition of serial fluoroscopic images from different angles which can be used to create 3D images. To increase the longitudinal coverage, we apply a segmental scanning pattern in which the imaged region is scanned in segments and stitched. To address the issue of data inaccuracy between the segments, redundant areas are set at margins of the segmental images, and registration and stitching algorithms are applied. We conducted validation experiments to evaluate radiation dose and image quality. The dose was evaluated using the volume CT dose index (CTDIvol). For image quality evaluation, we measured the low-contrast and spatial resolution. Additionally, we conducted a clinical study consisting of 30 volunteers with adolescent idiopathic scoliosis who were imaged by our method, and the images were subjectively assessed based on image noise, artifacts, anatomical coverage, diagnostic confidence, and overall quality. The CTDIvol was 1.23 mGy, and the low-contrast resolution was 0.6% at 4 mm and the spatial resolution was 8 lp/cm. The clinical images were generally of good quality, with high scores for all factors evaluated. Our method successfully generates large-coverage, weight-bearing, and 3D images of the whole spine with high image quality and low radiation dose. It shows potential for wider clinical applications for various musculoskeletal conditions.

Для цитирования: Liang Zejun, Xia Chunchao, Wang Qian, Chen Zengtong, Zhang Yu, Ye Chao, Zhang Yiteng, Yang Jie, Wang Hairong, Zheng Han, Du Jing, Li Zhenlin, Tang Jing. Weight-bearing cone-beam CT with extensive coverage for volumetric imaging in adolescent idiopathic scoliosis: system implementation and initial validation.. Physical and engineering sciences in medicine. 2023. DOI: 10.1007/s13246-023-01313-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.