MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1055/s-0033-1350862

Медицинская библиотека · Zeitschrift fur Orthopadie und Unfallchirurgie · 2013

[Anatomic reconstruction of hip joint biomechanics with the bone preserving Silent Micro Hip™ prosthesis].

Ries C, Schopf W, Dietrich F, Franke S, Jakubowitz E, Sobau C, Heisel C

Контролируемое клиническое исследованиеАннотация на английскомСтатьяПеревод в очереди

Аннотация

BACKGROUND

The design and the surgical technique of the Silent Micro Hip™ are different compared to other hip stems due to a conical shape for fixation within the metaphyseal femur. The purpose of the present study was to evaluate hip joint biomechanics of the Silent Micro Hip™ in comparison to other implants. Implant-specific differences are highlighted.

MATERIAL AND METHOD: 150 consecutive patients (each group 50 Silent Micro Hip™, Nanos™ and SL-Plus™ MIA) were analysed retrospectively. For evaluation of biomechanical parameters pre- and postoperative X-rays (pelvic AP views) were used.

RESULTS

The horizontal femoral offset and the limb length showed no significant difference between the Silent Micro Hip™ and the Nanos™ or SL-Plus™ MIA stem at the reconstructed hip. An almost anatomic reconstruction of hip joint biomechanics was reached with all three types of implants.

CONCLUSIONS

The Silent Micro Hip™ allows for almost anatomic reconstruction of hip joint biomechanics. Short-term results support the bone-preserving reconstruction with a proximal femoral load transfer. Further studies on the mid- and long-term outcomes are ongoing.

Для цитирования: Ries C, Schopf W, Dietrich F, Franke S, Jakubowitz E, Sobau C, Heisel C. [Anatomic reconstruction of hip joint biomechanics with the bone preserving Silent Micro Hip™ prosthesis].. Zeitschrift fur Orthopadie und Unfallchirurgie. 2013. DOI: 10.1055/s-0033-1350862.