OBJECTIVE

We review our experience with the use of the plate and screw method of fixation in the treatment of 160 patients with atlantoaxial instability during a 14-year period at our center. We previously described this method of fixation in 1994.

METHODS

Between 1988 and 2001, 160 patients with atlantoaxial instability were treated with the use of a plate and screw method of fixation at the Department of Neurosurgery at King Edward Memorial Hospital in Bombay, India. The study group was composed of 91 males and 69 females (mean age, 23 yr; age range, 18 mo-79 yr). Atlantoaxial instability was a result of congenital abnormality in 132 patients (83%) and occurred after trauma in 28 patients (17%). All patients had mobile, completely reducible atlantoaxial dislocation. For 3 months postoperatively, a hard cervical collar was used. The mean follow-up period was 42 months (range, 4 mo-14 yr).

RESULTS

Three patients died in the postoperative phase. Successful stabilization of the atlantoaxial region was documented with dynamic radiography in the other 157 patients. There was no incidence of implant rejection. In one patient, one screw was found to be broken 18 months after surgery; however, firm bony fusion was documented in this patient. There were no neurological, vascular, or infective complications.

CONCLUSION

The plate and screw method of fixation with the use of intra-articular bone grafts in patients with atlantoaxial instability yielded a 100% fusion rate with a low incidence of complications.

Для цитирования: Goel Atul, Desai Ketan I, Muzumdar Dattatraya P. Atlantoaxial fixation using plate and screw method: a report of 160 treated patients.. Neurosurgery. 2002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.