DOI 10.3171/jns.1995.82.3.0401
Continuous intraoperative electromyographic recording during spinal surgery.
Аннотация
One hundred fifty patients underwent spinal surgery for radiculopathy; of these, 120 underwent lumbar surgery and 30 had cervical operations. All of the surgeries were performed to alleviate symptoms due to disc herniation, spondylosis, or both. During the surgical procedures continuous intraoperative electromyograph recordings were taken from the muscle corresponding to the involved nerve root. In baseline recordings taken in the operating room 10 minutes before lumbar surgery, electrical discharge or firing was recorded from the muscle in 18% (22 of 120 patients) of the cases. Once the nerve was decompressed, muscle firing ceased. Electrical discharges were produced with regularity on nerve root retraction. This study concludes that continuous electromyograph monitoring can be accomplished easily and yields valuable information that indicates when the nerve root is adequately decompressed or when undue retraction is exerted on the root.