MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00264-024-06370-7

Медицинская библиотека · International orthopaedics · 2024

Safety and reliability of ultrasound-assisted reduction in the conservative management of completely displaced paediatric distal radius fractures.

Lin Yudong, Chen Saiwen, Zhang Zhuqing, Zhou Cheng, Gu Ran, Li Yangyang, Zhang Sicheng

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: To assess the efficacy of ultrasound-assisted reduction in the conservative management of completely displaced pediatric distal radius fractures.

METHODS

The efficacy of ultrasound-assisted reduction versus conventional reduction was compared in a single-centre, retrospective, cross-sectional study involving 51 consecutive paediatric patients with completely displaced distal radius fractures, following manual reduction, from May 2021 to May 2023. The study group received ultrasound-assisted reduction (n = 24), while the control group underwent conventional blind manual reduction (n = 27). Comparative analysis included general clinical data, initial reduction success rates, frequency of exposure to radiation during reduction, post-reduction alignment rates, post-reduction angulation, re-displacement rates, conservative treatment failure rates, pain scores, and wrist joint scores at the last follow-up.

RESULTS

All enrolled cases underwent manual reduction and conservative management. In the study group, all 24 patients underwent successful initial reduction procedures, with only one exposure to radiation during the entire process. Notably, no patient experienced re-displacement while in plaster, and the conservative treatment proved effective. The reduction and positioning rates were impressive, with success rates of 86.63 ± 3.65% in the coronal plane and 94.79 ± 3.06% in the sagittal plane. Furthermore, the post-reduction angulation was only 3.58 ± 0.65 degrees in the coronal plane and 8.70 ± 1.45 degrees in the sagittal plane. By contrast, within the control group comprising 27 patients, only 15 achieved successful initial reductions. Unfortunately, 12 patients required multiple exposure to radiation throughout the procedure. Furthermore, nine patients underwent re-displacement while in plaster and seven did not achieve successful conservative treatment. The alignment rates of the control group were similar to those of the study group (84.67 ± 4.35% in the coronal plane and 82.56 ± 5.45% in the sagittal plane). Similarly, the post-reduction angulation remained consistent, measuring 3.93 ± 0.87 degrees in the coronal plane and 12.03 ± 1.32 degrees in the sagittal plane. There were no statistically significant differences in pain scores during the process of fracture reduction and in wrist joint function scores at the final follow-up (P > 0.05).

CONCLUSION

Ultrasound-assisted reduction in the conservative management of completely displaced paediatric distal radius fractures can enhance the initial reduction success rate, decrease the risk of subsequent redisplacement, minimize patient exposure to radiation, and yield favorable clinical outcomes. It is a safe and reliable approach.

Для цитирования: Lin Yudong, Chen Saiwen, Zhang Zhuqing, Zhou Cheng, Gu Ran, Li Yangyang, Zhang Sicheng. Safety and reliability of ultrasound-assisted reduction in the conservative management of completely displaced paediatric distal radius fractures.. International orthopaedics. 2024. DOI: 10.1007/s00264-024-06370-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.