STUDY

DESIGN

A prospective single-surgeon nonrandomized clinical study.

OBJECTIVE

To evaluate the radiographic and clinical outcomes, by fixation type, in extreme lateral interbody fusion (XLIF) patients and provide an algorithm for determining patients suitable for stand-alone XLIF.

SUMMARY OF BACKGROUND DATA: XLIF may be supplemented with pedicle screw fixation, however, since stabilizing structures remain intact, it is suggested that stand-alone XLIF can be used for certain indications. This eliminates the associated morbidity, though subsidence rates may be elevated, potentially minimizing the clinical benefits.

MATERIALS AND

METHODS

A fixation algorithm was developed after evaluation of patient outcomes from the surgeon's first 30 cases. This algorithm was used prospectively for 40 subsequent patients to determine the requirement for supplemental fixation. Preoperative, postoperative, and 12-month follow-up computed tomography scans were measured for segmental and global lumbar lordosis and posterior disk height. Clinical outcome measures included back and leg pain (visual analogue scale), Oswestry Disability Index (ODI), and SF-36 physical and mental component scores (PCS and MCS).

RESULTS

Preoperatively to 12-month follow-up there were increases in segmental lordosis (7.9-9.4 degrees, P=0.0497), lumbar lordosis (48.8-55.2 degrees, P=0.0328), and disk height (3.7-5.5 mm, P=0.0018); there were also improvements in back (58.6%) and leg pain (60.0%), ODI (44.4%), PCS (56.7%), and MCS (16.1%) for stand-alone XLIF. For instrumented XLIF, segmental lordosis (7.6-10.5 degrees, P=0.0120) and disk height (3.5-5.6 mm, P<0.001) increased, while lumbar lordosis decreased (51.1-45.8 degrees, P=0.2560). Back (49.8%) and leg pain (30.8%), ODI (32.3%), PCS (37.4%), and MCS (2.0%) were all improved. Subsidence occurred in 3 (7.5%) stand-alone patients.

CONCLUSIONS

The XLIF treatment fixation algorithm provided a clinical pathway to select suitable patients for stand-alone XLIF. These patients achieved positive clinical outcomes, satisfactory fusion rates, with sustained correction of lordosis and restoration of disk height.

Для цитирования: Malham Gregory M, Ellis Ngaire J, Parker Rhiannon M, Blecher Carl M, White Rohan, Goss Ben, Seex Kevin A. Maintenance of Segmental Lordosis and Disk Height in Stand-alone and Instrumented Extreme Lateral Interbody Fusion (XLIF).. Clinical spine surgery. 2017. DOI: 10.1097/bsd.0b013e3182aa4c94.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.